Attention!
When device is in operation, cover of tank must be fully closed.
Attention!
In order to fill fuel tank with pellets, contact thermostat must be set to zero and fan must be
turned off.
If fuel meets the standards and recommendation of manufacturer, ash will fall into ash chamber. If fuel doesn't meet
the standards, requirements and manufacturer's instructions, there can be malfunctions of burning process, buildup of
condensate, soot and resin.
Electronic programmable thermostat is designed for adjustments of temperature in the premises. In order to find out
how to program the thermostat, read its manual, which is included with manual of every boiler.
When the bunker is out of fuel or fire of the burner is out, turn of the fan by following the instructions (set the contact
thermostat to 0
o
C), remove the ash and soot out of boiler. If boiler will not be used for longer period of time (for
example, when heating season is over), use up all the fuel from the bunker. Heat exchange medium mustn't be
removed from the heating system before the downtime period.
In cases of boiler malfunction, for example, when heat exchanger medium exceeds 100
exchanger medium is partly evaporated or when sounds, made by boiler, are heard in heating system), cracked pipes,
radiators, valves or if there is other danger of unsafe operation of boiler, user needs to:
Assure maximum cooling of boiler room by opening doors, windows, hatches, loading holes, etc.
Turn off the fan.
Eliminate the problem.
Check the level of heat exchanger medium in heating system and after boiler cools down, fill it up if needed.
If there is a need to pour some of cold heat exchanger medium into cold one (after losing large amounts), while boiler is
working, wait till boiler cools down, fill up the system of heat exchanger medium, carry out preparation works and
reignite the boiler. If cold heat exchanger medium touches hot wall of boiler, there is possibility of damage to the boiler.
7.4. Setting of thermostat of premises
7.5. How to stop the flow of pellets
7.6. Shutting down the boiler
7.7. Emergency shut down of boiler