Stropuva S7 Technical Passport, Installation And Maintenance Instruction

Stropuva S7 Technical Passport, Installation And Maintenance Instruction

Solid fuel boiler for central heating

Advertisement

Solid fuel boiler for
central heating
STROPUVA
TECHNICAL PASSPORT,
INSTALLATION AND MAINTENANCE
INSTRUCTION

Advertisement

Table of Contents
loading

Summary of Contents for Stropuva S7

  • Page 1 Solid fuel boiler for central heating STROPUVA TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION...
  • Page 2: Table Of Contents

    HEATING SYSTEM DIAGRAM ........................11 DIAGRAM OPERATION EXPLANATION ..................12 Connection diagram of „Stropuva“ boiler to another boiler, water heater and floor heating ..13 Connection diagram of „Stropuva“ boiler to another boiler, water heater, radiator, floor heating.14 Connection diagram of „Stropuva“ boiler to another boiler, water heater and radiator ....15 FIRING AND FUELING THE BOILER......................
  • Page 3: Technical Specifications

    • “U’’ universal (firewood, coal, peat and sawdust briquettes, pellets, wood chips); • “BIO’’ (firewood, sawdust briquettes, pellets, wood chips); with six 7 kW; 10 kW; 12 kW; 20 kW; 30 kW; 40kW power capacities. Boilers “Stropuva’’ can be used to heat premise area ranging from 100 to 400 m MAIN TECHNICAL SPECIFICATIONS Fuel used: firewood, wood residue, sawdust briquettes, peat briquettes, coal, pellets.
  • Page 4 ** Power of boiler is selected according to area of premise. For example, if in Stropuva S20 solid fuel boiler built in 200 m building with one load burns 24 hours, then one load of firewood in Stropuva S40 solid fuel boiler would burn for almost 48 hours.
  • Page 5: Boiler Structure

    TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION BOILER STRUCTURE 1. Air valve 2. Draft regulator 3. Support rod 4. Air heating chamber 5. Smoke outlet 6. Switch valve (only for U boilers) 7. Telescopic air supply pipe 8. Fuel loading opening 9.
  • Page 6: Boiler Parts

    TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION At the upper part of the chamber there’s an air opening and air valve (1). On the right side of the boiler, in front of the door, there is a lifting cord with ring (12) responsible for the air supply mechanism and hook (13) for fixation of the cord.
  • Page 7: Fire Grate

    Put the fire grate (19) (Fig. 1); (Fig. 7), at the bottom of universal and “BIO’’ when burning firewood. When buying universal and “BIO’’ solid fuel boiler “Stropuva’’ this part in included. Important to know when changing the fire grate is that it is composed of two separate parts.
  • Page 8: Deflectors

    TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION DEFLECTORS Deflectors (crescents) 2 units (Fig. 8) are designed to increase efficiency of the boiler. After installing the boiler, we recommend putting deflectors (20) (Fig. 1) through the upper fuel loading door (8) (Fig. 1) on the bottom edge of the air heating tank. Figure 8 SAFETY VALVE 1.5 BAR.
  • Page 9: Transportation And Storage

    TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION TRANSPORTATION AND STORAGE Loose boilers are allowed to be transported only in horizontal position. During good weather seasons the boilers can be transported by open transport, otherwise the products need to be covered. When transporting in vertical position additional safety measures have to be taken in account to prevent turning or scratching.
  • Page 10: Requirements For Connection To The Heating System

    TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION We recommend: • Install stainless steel liner inside the chimney - correctly installed liner protects the chimney from condensation and moisture; • Liner should not significantly reduce the diameter of chimney’s opening; • Parts of the liner must be well connected between each other (using stainless steel rivets); •...
  • Page 11: Heating System Diagram

    TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION HEATING SYSTEM DIAGRAM Stropuva Figure 10...
  • Page 12: Diagram Operation Explanation

    TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION DIAGRAM OPERATION EXPLANATION Pump (P) pulls water from heating elements and pushes it through boiler and into heating elements. Through balance tap (bk1) hot water goes to the closest radiator which can operate in self-contained way in order to protect the boiler in case of power loss (radiator has no temperature valve).
  • Page 13: Connection Diagram Of „Stropuva" Boiler To Another Boiler, Water Heater And Floor Heating

    15. Thermostatic head 20 - 50 °C - 1 pcs. For boilers S7, S10, S12, S20, S7 BIO, S10 BIO, S20 BIO and S10U, S12U, S20U, nodes are assembled from parts D20. For boilers S30, S30 BIO and S30U, S40, S40 BIO and S40U nodes...
  • Page 14: Connection Diagram Of „Stropuva" Boiler To Another Boiler, Water Heater, Radiator, Floor Heating.14

    15. Thermostatic head 20 - 50 °C - 2 pcs. For boilers S7, S10, S12, S20, S7 BIO, S10 BIO, S20 BIO and S10U, S12U, S20U, nodes are assembled from parts D20. For boilers S30, S30 BIO and S30U, S40, S40 BIO and S40U nodes...
  • Page 15: Connection Diagram Of „Stropuva" Boiler To Another Boiler, Water Heater And Radiator

    R - to/out of radiator For boilers S7, S10, S12, S20, S7 BIO, S10 BIO, S20 BIO and S10U, S12U, S20U, nodes are assembled from parts D20. For boilers S30, S30 BIO and S30U, S40, S40 BIO and S40U nodes...
  • Page 16: Firing And Fueling The Boiler

    FUEL BURNS MOST EFFICIENTLY WHEN COMBUSTION CHAMBER IS FULLY LOADED Stropuva “U’’ boiler has a switch valve (6) (Fig. 1), which, when burning coal must be raised on the support (Fig. 14), when burning firewood – lowered. Firewood boiler and “BIO’’...
  • Page 17: Recommendations When Firing Universal ''Stropuva" Boiler

    - to let it rest on the fuel. This will enhance the longevity of the air distributor. ATTENTION! RECOMMENDATIONS WHEN FIRING UNIVERSAL ‘‘STROPUVA“ BOILER Air valve that lets air flow under fire grate (19) (Fig. 1) is controlled with the help of switch valve (6) (Fig.
  • Page 18: Assessment Of Boiler Operation

    TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION get hotter, cylinder becomes longer and lowers the valve. When indications of thermometer becomes stable under 80 °C, slightly open the valve by using temperature adjustment bolt (2) if temperature is higher than 80 °C – slightly close it till temperature falls under 80 °C.
  • Page 19: Safety Equipment Requirements

    TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION distributor (9) (Fig. 1), would be lifted more easily. We also recommend oiling the closing door hooks. Sometimes, it needs to be checked if the doors seals uniformly. In order to make doors seal uniformly, gasket needs to be changed or lock tabs need to be adjusted. SAFETY EQUIPMENT REQUIREMENTS Boiler room is a zone of increased hazard.
  • Page 20: Risk Assessment

    TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION RISK ASSESSMENT HEAT HAZARDS Touching hot elements of boiler can cause burns. Boiler’s surface area, which heats up to 40 °C and other parts are thermally isolated given the technical possibilities, but there are other parts such as door handles which get even hotter and are dangerous to humans.
  • Page 21: Accessories

    Per request of a client a pellet burner with all needed equipment can be connected to every solid fuel boiler “Stropuva”. You won’t have to buy a new boiler - all it takes is to modernize the older boiler “Stropuva”. The boiler retains the ability to use firewood, briquettes and coal.
  • Page 22: Package Content

    TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION PACKAGE CONTENT PACKAGE CONTENT (Firewood boiler) Solid fuel boiler ‘‘STROPUVA“ – 1 pcs. • Safety pressure valve 1,5 bar – 1 pcs. • Thermometer – 1 pcs. • Deflectors – 2 pcs. • Air distributor – 1 pcs.
  • Page 23: Product Warranty Conditions

    • To preserve warranty agreement and its entries. We recommend that the installation assessment, the first start-up / adjustment of the boiler be performed by certified UAB “Stropuva ir ko’’ specialist. Manufacturer cannot be held responsible for the operation of boiler and consequences arising out of using it, and is not providing warranty in such cases: •...
  • Page 24: Warranty Certificate

    TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION WARRANTY CERTIFICATE JSC “Stropuva ir ko’’, Company code 300149972 MANUFACTURER: Address: Kęstučio g. 1A, Lentvaris, Trakų distr. LT-25144 Lithuania tel.: +370 525 51763 Boiler model: Product number: Date of sale / Signature / Stamp...
  • Page 25 TECHNICAL PASSPORT, INSTALLATION AND MAINTENANCE INSTRUCTION WARRANTY / POST WARRANTY SERVICE Work carried out, Name / Surname / Date Organization replace parts Signature The boiler has a year warranty* *If the heat exchanger is broken, seller has to fix the boiler on its own expense, but if other components are broken not due to the fault of the end user, customer has to disassemble the part and the seller has to change the part without installation or the seller suggests paid qualified services.
  • Page 26 JSC “Stropuva ir ko’’, company code 300149972, Kęstučio g. 1A, Lentvaris, Trakų distr. LT-25144 Tel. +370 5 255 17 63, mob. +370 656 08961 www.stropuva.lt info@stropuva.lt...

Table of Contents