electronics lovers, it is possible to use sophisticated room thermostats remotely controlled, even by computer or mobile
phone. I would like to use such devices, follow their instructions.
3. Wiring room thermostat connector. A trumpet was killed by using another set of shirts, a cord, a room thermostat.
Room thermostats can be connected directly to the terminals in the box.
4. Thermostat for hot water coming out of the boiler. Installed on top of the outlet hot water pipe. The thermostat
keeps the boiler from overheating, so set it at 80 ° C.
5. Return water thermostat. It is mounted on the bottom of the boiler. Before setting this thermostat, set the room
thermostat to the highest T or do not use it. Set the return water thermostat approximately (say 25 ° C T). If the boiler
thermostat switches off the burner to the remaining room before the required level, set the temperature higher to 2-3 °
C. If there is not enough heat in the room, increase the thermostat T until the room reaches the desired heat. In this
way, the heat remains the same as changing the field T, because (you can experiment when windows open) or when the
field T radiators are cooled down, the burners will continue to work longer while the returning tasks T are working
longer (and vice versa) while maintaining constant heat in the premises.
However, sometimes when the room is warmed up in the open air, heated in the sun or on the stove, and other heat-
transmitting devices, the room heats up for longer and longer, then the burner switches off the room thermostat. It is
useful to set the room thermostat a little above the room (according to the room thermometer) during the day, and at
night for the night.