5. CONNECTION TO HYDRAULIC SYSTEM

5.1. Installation in closed system
According to requirements of this manual, boiler is allowed to be used in closed system only after installing specific
safety devices.
On our boiler (on back side, near the flue) there is ½ inch connection for protection system.
Manufacturer does not take responsibility for quality, selection and appropriate installation of devices for protection
from higher temperature than 95
O
C and higher pressure than 1,5 bar.
This work can only be carried out by authorized qualified technician.
For safety, we recommend a thermal protection device Laddomat 5067.

6. ELECTRICAL INSTALLATION

Operated boiler "Pellet boiler" must be connected to working electrical system which completely complies with laws of
Country in which it is operated.
In case of bad installation, controller can be damaged or damage can be done to people and environment. Controller
and device need 230 V power supply, therefore installation works must be carried out by a person with appropriate
knowledge, skills and who meets additional requirements of Country in which the boiler is installed.

7. OPERATION OF BOILER

7.1 General information
User must have operational accessories of boiler, for example, scoop, cleaning rod, also he/she must be wearing
personal protection clothes, at least gloves.
It is forbidden to alter boiler's construction or operational principle, also to add other – not factory installed and not
manufacturer's recommended – equipment, because boiler can fail or be damaged.
Before testing the boiler, all heating system must be filled with heat exchanging medium.
This part must be carried out by complying with all instructions of device and current regulations.
Before lighting the burner, check if the system is correctly loaded and looking orderly.
Also you must inspect the condition of chimney.
Boiler can be inspected by installer or qualified technician.
Use only dry fuel. Wet fuel can get stuck in storage – there will be more smoke while burning and boiler will wear out
faster.