Position Planning Of The Digital Infrared Receiver; Position Away From Lighting Equipment; Avoid Direct Intense Light; Example For Planning The Receiver - Taiden TES-5604 Series Installation And Operating Manual

Classroom
Table of Contents

Advertisement

1.4 Position planning of the digital infrared receiver

1.4.1 Position away from lighting equipment

Although classroom audio system has good
anti-interference performance to ambient light, the
distance of the receiver from lighting equipment must be
at least 50 cm to guarantee adequate intensity and
stability of infrared signals.
Figure 1.3 Digital infrared receiver position (near lighting
equipment)
Note:
 If the position of lighting equipment is higher
than the position of the receiver, the disturbance
can be ignored.

1.4.2 Avoid direct intense light

Exposing the receiver to intense light source may
cause system failure or noise. Please do not mount the
receiver in such a way the intense light source
irradiates directly, as shown in follow figure:
Figure 1.4 Digital infrared receiver position (avoid direct
intense light)
D

1.4.3 Example for planning the receiver

The reception angle of the digital infrared receiver is
150°in vertical and 360°in horizontal. For a good
reception, please plan the receiver according to the
teaching environment.
【8m×8m classroom】
In an 8m×8m classroom, one receiver can be mounted
on the ceiling in the front middle part of the classroom
and about 2 to 3 meters (L) away from the blackboard.
Figure 1.5 Planning the receiver 1
【15m×15m classroom】
In a 15m×15m classroom, two receivers with a distance
of 6 to 8 meters(D) between them, can be mounted on
the ceiling in the front middle part of the classroom, 2 to
3 meters (L) away from the blackboard.
Figure 1.6 Planning the receiver 2
Note:
 TES-5685M must be mounted on the ceiling in
the front middle part of the classroom, more
than 3 meters (L) away from the blackboard.
4