Locating Your Gas Fireplace

1. When selecting a location for your fireplace,
ensure that the clearances are met.
2. The appliance must be installed on a flat, solid,
continuous surface For example a timber, metal
or concrete floor or in a raised (on the wall) ap-
plication. The appliance must be installed on a
metal or timber panel extending the full width
and depth of the appliance.
3. The ACV40E Direct Vent Gas Fireplace can be
installed in a recessed position or framed out
into the room as in A, B, C, D.
See Diagram 1.
A) Flat on Wall-ACV40E
B) Flat on Wall Corner-ACV40E
C) Recessed into Wall/Alcove-ACV40E
D) Corner-ACV40E
E
Diagram 1
4. For bedroom installations, check with local
codes before installation. This appliance is
offered with a remote control.
5. The ACV40E Direct Vent Gas Fireplace is ap-
proved for alcove installations, see "Clearances"
section for details.
6. We recommend that you plan your installa-
tion on paper using exact measurements for
clearances and floor protection before actually
installing this appliance. Have an authorized
inspector, dealer, or installer review your plans
before installation.
Note:
For vent terminations refer to "Exterior
Vent Termination Locations" section.

Unit Assembly Prior to Installation

Before you start
The ACV40E has 6 standoffs, 2 on each side and 2 at the back that need assembly before installation.
WARNING! Risk of Fire! Comply with all minimum clearances.

Side and Back Standoff Assembly

The standoffs are shipped in a flat position and must be folded into shape and attached.
Take each standoff off the unit by removing one screw and bend into the correct shape. Slot the 2 tabs
of the stand off into the slots in the unit and attach the other end with one screw.

Nailing Strips

Nailing strips are shipped folded flat against the unit.
Fold nailing strips out 90º before installing unit.
Secure nailing strips to framing using wood or
metal screws.