Omron NX Series User Manual page 52

Machine automation controller system units
Hide thumbs Also See for NX Series:
Table of Contents

Advertisement

3 Part Names and Functions
Letter
(A)
Terminal number indi-
cations
(B)
Release holes
(C)
Terminal holes
(D)
Ground terminal mark
The NX-TB
The NX-TB
To differentiate between the two models of Terminal Blocks, use the terminal number column indica-
tions. The Terminal Block with white letters on a dark background is the NX-TB
You can mount either NX-TB
capacity specification of the terminals is 4 A or less.
You can only mount the NX-TB
cation of the terminals is greater than 4 A.
Additional Information
• Each power supply-related Unit is compatible with only one of three types of terminal
blocks. You cannot use a terminal block with a number of terminals that differs from the
specifications for a particular Unit.
• The 8-terminal type does not have terminal holes and release holes for following terminal
numbers.
A2, A4, A6, A8, B2, B4, B6, and B8
3 - 4
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Name
Terminal numbers for which A and B indicate the column, and 1 to 8 indi-
cate the line are displayed.
The terminal number is a combination of column and line, i.e. A1 to A8
and B1 to B8.
The terminal number indications are the same regardless of the number
of terminals on the terminal block.
Insert a flat-blade screwdriver into these holes to connect and remove the
wires.
The wires are inserted into these holes.
This mark indicates ground terminals. It is only on the NX-TBC
2 and NX-TB
1 Terminal Blocks have different terminal current capacities.
2 has 10 A and NX-TB
1 or NX-TB
2 Terminal Block to the Units that the current capacity specifi-
Function
1 has 4 A.
2 Terminal Blocks to the Units that the current
NX-series System Unit User's Manual (W523)
2.
2.

Advertisement

Table of Contents
loading

Table of Contents