Siemens SINUMERIK 840D sl Series Diagnostics Manual page 536

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
Error code = 4 : Machine date $MC_MM_NUM_CC_BLOCK_ELEMENTS or
$MC_MM_NUM_CC_BLOCK_USER_MEM must be increased.
Error code = 5 : Insufficient heap memory for compile cycles available. Adjust machine
data $MC_RESU_RING_BUFFER_SIZE, $MC_RESU_SHARE_OF_CC_HEAP_MEM
and $MC_MM_NUM_CC_HEAP_MEM.
Error code = 6 : The machine data $MN_ASUP_START_MASK and
$MN_ASUP_START_PRIO_LEVEL are not set correctly.
Error code = 11: Machine data $MC_AXCONF_GEOAX_NAME_TAB[n],
$MN_INTERMEDIATE_POINT_NAME_TAB[n] and $MN_IPO_PARAM_NAME_TAB[n]
are not set correctly for RESU:
Error code = 13: With bit 2 = 0 of MD $MC_RESU_SPECIAL_FEATURE_MASK it was
specified that the retraction program cc_resu.mpf is to be stored in the DRAM parts pro-
gram memory. However, no DRAM parts program memory was requested via MD
$MN_MM_DRAM_FILE_MEM_SIZE. Remedy: Either set MD
$MN_MM_DRAM_FILE_MEM_SIZE to a value inequal to zero or set bit 2 of MD
$MC_RESU_SPECIAL_FEATURE_MASK equal to one.
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Correct machine data.
Program Con-
Switch control OFF - ON.
tinuation:
75601
Channel %1 block %2 invalid parameter in CC_PREPRE()
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Only the values _1, 0, 1 are valid parameters for CC_STOPRE().
Reactions:
- Interpreter stop
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
75604
Channel %1 RESU: Return traveling not possible, error code %2
Parameters:
%1 = Channel number
%2 = Error code
Definitions:
Return traveling is not possible, as the following error was detected:
Error code = 1 : The current reverse block for return traveling is likely to be a block of
cc_resu_ini.spf or cc_resu_end.spf programmed with a block number. It is impermissible
to program block numbers in the subroutines cc_resu_ini.spf and cc_resu_end.spf, as
they have an internal meaning.
Error code = 2 : Unable to create cc_resu.mpf, as DRAM is insufficient.
Error code = 4 : The selected continuation block is likely to be a block of cc_resu_ini.spf or
cc_resu_end.spf programmed with block number. It is impermissible to program block
numbers in the subroutines cc_resu_ini.spf and cc_resu_end.spf, as they have an inter-
nal meaning.
Reactions:
- NC Start disable in this channel.
- Interface signals are set.
2-536
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved