08/2005
208511
<location>COMM BOARD: Receive configuration data not valid
Reaction:
NONE
Acknowledge:
NONE
Cause:
The drive unit did not accept the receive-configuration data.
Alarm value (r2124, decimal):
Return value of the receive-configuration data check.
0: Configuration accepted.
1: Drive overflow.
2: Data length overflow.
3: Data length uneven.
4: Setting data for synchronization not accepted.
5: Drive still not in cyclic operation.
6: Buffer system not accepted.
7: Cyclic channel length too short for this setting.
8: Cyclic channel address not initialized.
9: 3-buffer system not permitted.
10: DRIVE-CLiQ fault.
11: CU link fault.
12: CX32 not in cyclic operation.
Remedy:
Check the receive configuration data.
208520
<location>COMM BOARD: Non-cyclic channel error
Reaction:
NONE
Acknowledge:
NONE
Cause:
The memory or the buffer status of the non-cyclic channel has an error.
Alarm value (r2124, decimal):
0: Error in the buffer status.
1: Error in the memory.
Remedy:
Check communication line.
208530
<location>COMM BOARD: Message channel error
Reaction:
NONE
Acknowledge:
NONE
Cause:
The memory or the buffer status of the message channel has an error.
Alarm value (r2124, decimal):
0: Error in the buffer status.
1: Error in the memory.
Remedy:
Check communication line.
208700
<location>CBC: Communications error
Reaction:
OFF3 (NONE, OFF1, OFF2)
Acknowledge:
IMMEDIATELY
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-713