Description
STOP1
Reaction
-
Description
Available soon
Description
STOP2
Reaction
n_set = 0
• n_set=0 is input immediately to brake the drive along the OFF3 deceleration ramp
Description
(p1135).
• The drive remains in closed-loop speed control mode.
Description
DCBRAKE
Reaction
-
Description
Available soon
Description
ENCODER
Reaction
Internal/external pulse disable (p0491)
Description
The fault reaction ENCODER is applied as a function of the setting in p0491.
Factory setting:
p0491=0 --> Encoder fault results in OFF2
Acknowledging faults (alarms)
Indicates the standard acknowledgement of the fault after removal of the cause.
For an overview of parameters and function block diagram, please refer to the fol-
lowing publication:
LIS1, Lists 1
Description
POWER ON
• The fault is acknowledged by a POWER ON process (switch drive unit off and on
Description
again).
Note:
If this action has not eliminated the fault cause, the fault is displayed again immediately
after power up.
Description
IMMEDIATELY
Description
After correction of the fault, the alarm can be cleared by pressing the RESET key:
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
System Reactions on Alarms
System reactions on SINAMICS alarms
5-993