Siemens SINUMERIK 840D sl Series Diagnostics Manual page 293

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Reactions:
- Alarm display.
Remedy:
Delete the "Global start disable" and restart.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
16957
Channel %1 Stop-Delay area is suppressed
Parameters:
%1 = Channel ID
Definitions:
The program area (Stop-Delay area), which is put into brackets through DELAYFSTON
and DELAYFSTOF, could not be activated. Every stop therefore becomes effective
immediately
and is not delayed!
This occurs every time, when braking into a stop Stop-Delay area, i.e. a braking process
starts before the Stop-Delay area and ends not earlier than in the Stop-Delay area.
If the Stop-Delay area is entered with override 0, the Stop-Delay area
can also not be activated (example: a G4 before the Stop-Delay area allows the user
to reduce the override to 0 and the next block in the Stop-Delay area
then starts with override 0 and the alarm situation described occurs.)
$MN_ENABLE_ALARM_MASK Bit-7 switches on this alarm.
Reactions:
- Interface signals are set.
- Alarm display.
Remedy:
$MN_STOP_MODE_MASK and language command DELAYFSTON DELAYFSTOF
Program Con-
Alarm display showing cause of alarm disappears. No further operator action necessary.
tinuation:
16959
Channel %1 action %2<ALNX> prohibited during simulation block search.
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
The function (2nd parameter) must not be activated during simulation search.
Reactions:
- Alarm display.
Remedy:
Wait for search end.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
16960
Channel %1 action %2<ALNX> prohibited during EXECUTE PROGRAM AREA.
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
The function (2nd parameter) must not be activated during EXECUTE PROGRAM AREA.
Reactions:
- Alarm display.
Remedy:
Wait for end of program area EXECUTE.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
17000
Channel %1 block %2 maximum number of symbols exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-293