Configuring with Web Based Management
4.8 "Layer 3" menu
● Translated Source IP Address
Enter the IP address with which the IP address of the sender is replaced. Can only be edited
if "Use Interface IP from Destination Interface" is disabled.
● Destination IP Address(es)
Specify the destination IP addresses for which this source NAT rule is valid. Only the
packets whose destination IP address is in the range of entered addresses are taken into
account.
– IP address: Applies precisely to the specified IP address.
– IP address range: Applies to a certain IP address range: Start IP address "-" End IP
– IP subnet: Applies to several IPv4 addresses grouped together to form an IP address
The table has the following columns:
● Select
Activate the check box in the row to be deleted.
● Source Interface
Shows the source interface.
● Destination Interface
Shows the destination interface.
● Source IP Address(es)
Shows the IP addresses of the senders for which address translation is required.
● Use Interface IP
Shows whether the IP address of the selected destination interface is used in "Translated
Source IP Address".
● Translated Source IP Address
Shows the IP address with which the IP address of the sender is replaced.
● Destination IP Address(es)
Shows the IP addresses of the recipients for which address translation is required.
See also
NAT and firewall (Page 46)
240
address, e.g. 192.168.100.10 - 192.168.100.20
range: IP address/number of bits of the network part (CIDR notation)