Check The Drainage; Evaluation Of The Performance; Installation Of Anti-Bacterial Filter - Panasonic CS-RZ25VKRW Service Manual

Indoor/outdoor units
Hide thumbs Also See for CS-RZ25VKRW:
Table of Contents

Advertisement

12.2.8

Check the Drainage

Open front panel and remove air filters. (Drainage
checking can be carried out without removing the
front grille.)
Pour a glass of water into the drain tray-styrofoam.
Ensure that water flows out from drain hose of the
indoor unit.
12.2.9

Evaluation of the Performance

Operate the unit at cooling/heating operation
mode for fifteen minutes or more.
Measure the temperature of the intake and
discharge air.
Ensure the difference between the intake
temperature and the discharge is more than 8°C
during Cooling operation or more than 14°C
during Heating operation.

12.2.10 Installation of Anti-bacterial Filter

1
Open the front panel.
2
Remove the air filters.
3
Put the anti-bacterial filter into place as shown in illustrations below.
Anti-bacterial filter 7
Air filter
Applicable model MRZ16***, MRZ20***, RZ25***, RZ35***, RZ42***
Air filter
Applicable model RZ50***, RZ60***, RZ71***, RZ80***
67
Drain tray-styrofoam
Discharge air
Anti-bacterial filter 7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents