7.2
CS-RZ42VKRW CU-RZ42VKR CS-RZ50VKRW CU-RZ50VKR
CS-RZ60VKRW CU-RZ60VKR CS-RZ71VKRW CU-RZ71VKR

CS-RZ80VKR CU-RZ80VKR

INDOOR
INTAKE
TEMP.
SENSOR
HEAT EXCHANGER
(EVAPORATOR)
COOLING
HEATING
Temp. (°C)
Pipe Temp. (kΩ)
-15
148.40
5
51.16
15
31.52
20
25.02
25
20.00
30
16.10
45
8.71
PIPE
TEMP.
SENSOR 1
PIPE
TEMP.
SENSOR 2
(FOR Z80VK ONLY)
Indoor Sensor
Intake Air Temp. (kΩ)
111.27
38.37
23.64
18.77
15.00
12.07
6.53
RECEIVER
LIQUID
(FOR RZ71/80VKR
SIDE
ONLY)
2-WAY
DISCHARGE
VALVE
MUFFLER
(FOR RZ50VKR
ONLY)
GAS
SIDE
3-WAY
VALVE
COMPRESSOR
TEMP.
SENSOR
COMPRESSOR
Pipe Temp. (kΩ)
35.82
12.41
7.72
6.17
5.00
4.02
2.22
34
OUTDOOR
EXPANSION
VALVE
STRAINER
AIR
TEMP.
SENSOR
HEAT EXCHANGER
(CONDENSER)
4-WAY VALVE
DISCHARGE
MUFFLER
Outdoor Sensor
Air Temp. (kΩ)
Comp. Temp. (kΩ)
117.11
38.93
23.77
18.81
15.00
12.05
6.52
PIPE
TEMP.
SENSOR
390.36
129.75
79.22
62.69
50.00
40.18
21.72