Layout Of The Components; General; Current Carrying Capacity Of The Dc Link Busbar - Siemens SINAMICS S120M Manual

Distributed drive technology
Hide thumbs Also See for SINAMICS S120M:
Table of Contents

Advertisement

Cabinet design and EMC S120M

7.5 Layout of the components

7.5
Layout of the components
7.5.1

General

The arrangement of the components and equipment takes account of
● Space requirements
● Cable routing
● Bending radii of connecting cables
– For MOTION-CONNECT cables, refer to catalog PM21 and/or NC61
– Hybrid Cable: static 60 mm, dynamic 112.5 mm
● Heat dissipation
● EMC
The central components of the drive line-up should preferably be installed on a conductive
mounting surface to ensure a low impedance between the component and the mounting
surface. Mounting plates with a galvanized surface are suitable.
Components are usually located centrally in a cabinet. The necessary mounting and
installation clearances above an below the components can, under certain circumstances,
exceed the minimum clearances specified in the product documentation.
The components can be arranged in one or more tiers. In a multiple-tier arrangement,
vertical installation or, in a cabinet row, side-by-side installation in different cabinet sections
is possible.
To determine the cross-section, use the DC link busbar current carrying capacity specified in
the relevant technical data.
A ventilation clearance of 100 mm must be maintained around the line reactor (not including
the mounting surface).
7.5.2

Current carrying capacity of the DC link busbar

The current carrying capacity of the DC link busbar must be observed for the configuration
and arrangement of the drive line-up.
Table 7- 11
Maximum current carrying capacity of the DC link busbar
Current carrying capacity
of the DC link busbar
100 A
150 A
200 A
140
Components
Motor Modules from 50 mm to 100 mm wide
DC link components
Motor Modules from 50 mm to 100 mm wide with reinforced DC link busbars
Motor Modules from 150 mm to 300 mm wide
SINAMICS S120M Distributed Drive Technology
Manual, (GH12), 12/2014, 6SL3097-4AW00-0BP3