X24 24 V Terminal Adapter - Siemens SINAMICS S120M Manual

Distributed drive technology
Hide thumbs Also See for SINAMICS S120M:
Table of Contents

Advertisement

Cabinet design and EMC S120M
7.2 24 V DC supply voltage
7.2.3

X24 24 V terminal adapter

Table 7- 1
Terminal strip X24
Terminal
+
M
The 24 V terminal adapter is not included in the scope of delivery of the Adapter Module 600. It is included in the scope of
delivery of the Line Modules and Control Supply Modules (article number: 6SL3162-2AA00-0AA0).
Maximum cross section that can be connected: 6 mm
Type: Screw terminal 5 (see Chapter "Connectable conductor cross-sections for screw terminals (Page 135)")
Danger to life due to electric shock when connecting and disconnecting 24 V terminal
adapters and 24 V connections in operation
When opening plug connections in operation, arcs can result in severe injury or death.
• Only connect or disconnect the connections in a no-voltage state.
• Only remove the 24 V terminal adapter vertically in relation to the front plate.
• Disconnect and connect the connections a maximum of 5 times in a row.
Note
You can find other versions of 24 V terminal adapters and 24 V connections in Chapter
Adapter Module AM600/Electrical connection (Page 62).
120
Designation
24 V power supply
Ground
WARNING
Technical data
24 VDC supply voltage
Electronics ground
2
SINAMICS S120M Distributed Drive Technology
Manual, (GH12), 12/2014, 6SL3097-4AW00-0BP3