To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the "i
v
i
nside
ertical
nstallatiOns
- F
" section and then finish it by performing the following (refer to Figure 33).
reestanding
1. Install a tee with clean out on the outside of the house.
2. Install PL vent upward from the tee. Make sure that you install support brackets to keep the vent
straight and secure.
3. Install ceiling thimble and secure the flashing as you go through the roof.
4. Ensure that the rain cap is approximately 24" (610 mm) above the roof.
Rain cap
Flashing
24"
(61 cm)
3" (7.5 cm)
Clearance
3"
(7.5cm)
Support
bracket
Tee with
cleanout
Type "L"
vent
Fresh air
intake
Figure 33: Outside Vertical Installation.