OMNI-Test Laboratories, Inc.
BR – Average dry burn rate over full integrated test run, kg/hr
ASTM E2779 equation (3)
Where,
Sample Calculation:
58 of 194
Control No. P-SFDK-0002, Effective date: 5/06/2016
60 M
Bdb
BR
=
θ
θ
= Total length of full intergrated test run, min
M
= 5.36
kg
Bdb
θ
= 361
min
60 x 5.36
BR
=
361
BR
=
0.89
kg/hr
58 of 194
File - Run 1, Tab - Example Calculations