Sherwood Meridian Series Manual page 90

Pellet-fired, freestanding or insert
Table of Contents

Advertisement

v
t
R
ent
eRmination
eQuiRementS
IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER.
Table 1: Use in conjunction with Figure 13 for allowable exterior vent termination locations.
Letter
Minimum Clearance
A
24 in (61 cm)
B
48 in (122 cm)
C
12 in (30 cm)
D
24 in (61 cm)
E
24 in (61 cm)
F
12 in (30 cm)
G
12 in (30 cm)
H
3 ft (91 cm) within a height
of 15 ft (4.5 m) above the
meter/regulator assembly
I
3 ft (91 cm)
J
12 in (30 cm)
K
24 in (61 cm)
L
7 ft (2.13 m)
1. Do not terminate the
vent in any enclosed
or semi-enclosed areas
such
as
a
carport,
garage, attic, crawlspace,
narrow walkway, closely
fenced area, under a
sundeck or porch, or any
location that can build
up a concentration of
fumes such as stairwells,
covered breezeway, etc.
2. Vent surfaces can become
hot enough to cause burns if touched by children. Non-combustible shielding or guards may be required.
3. Termination must exhaust above the inlet elevation. It is recommended that at least five feet of vertical pipe
be installed outside when the appliance is vented directly through a wall, to create some natural draft to
prevent the possibility of smoke or odor during appliance shut down or power failure. This will keep exhaust
from causing a nuisance or hazard from exposing people or shrubs to high temperatures. In any case, the
safest and preferred venting method is to extend the vent through the roof vertically.
4. Distance from the bottom of the termination and grade is 12" (30 cm) minimum. This is conditional upon
the plants and nature of grade surface. The exhaust gases are hot enough to ignite grass, plants and
shrubs located in the vicinity of termination. The grade surface must not be lawn.
5. If the unit is incorrectly vented or the air to fuel mixture is out of balance, a slight discoloration of the
exterior of the house might occur. Since these factors are beyond the control of Sherwood Industries Ltd,
we grant no guarantee against such incidents.
NOTE: Venting terminals shall not be recessed into walls or siding.
Installation
:
Above grass, top of plants, wood, or any other combustible materials.
Beside/below any door or window that may be opened. (18" (46 cm) if outside
fresh air installed.)
Above any door or window that may be opened. (9" (23 cm) if outside fresh air
installed.)
To any adjacent building, fences and protruding parts of the structure.
Below any eave or roof overhang
To outside corner.
To inside corner, combustible wall (vertical and horizontal terminations).
To each side of center line extended above natural gas or propane meter/
regulator assembly or mechanical vent.
From any forced air intake of other appliance
Clearance to non-mechanical air supply inlet to building, or the combustion air
inlet to any appliance.
Clearance above roof line for vertical terminations.
Clearance above paved sidewalk or paved driveway located on public property.
D
F
Opens
B
Termination Cap
Air Supply Inlet
Figure 23: Use in conjunction with Table 1 for allowable exterior vent
Description
B
Opens
G
I
A
Restriction Zone
Gas Meter
G
(Termination not allowed)
termination locations.
G
K
E
G
C
L
Opens
H
19

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Meridian-1Meridian fpiMeridian cast ironGf55Gfi55

Table of Contents