OMNI-Test Laboratories, Inc.
– Total Particulate Emissions, g
E
T
ASTM E2515 equation (15)
(
)
=
E
c
c
Q
T
s
r
std
Where:
C
s
C
r
Q
std
θ
Sample calculation:
For Train 1
E
= ( 0.000102 -
T
E
=
5.18
T
For Train 2
E
= ( 0.000105 -
T
E
=
5.37
T
Average
E =
5.28
Total emission values shall not differ by more than 7.5% from the total average emissions
7.5% of the average =
Train 1 difference =
Train 2 difference =
65 of 194
Control No. P-SFDK-0002, Effective date: 5/06/2016
 
=
Concentration of particulate matter in tunnel gas, g/dscf
=
Concentration particulate matter room air, g/dscf
=
Average dilution tunnel gas flow rate, dscf/hr
=
Total time of test run, minutes
0.000000 ) x
g
0.000000 ) x
g
g
0.40
0.09
0.09
8469.6
x
361 /60
8469.6
x
361
/60
65 of 194