Sherwood Meridian Series Manual page 60

Pellet-fired, freestanding or insert
Table of Contents

Advertisement

OMNI-Test Laboratories, Inc.
– Average gas velocity in the dilution tunnel, ft/sec
V
s
ASTM E2515 equations (9)
=
V
F
K
s
p
Where:
F
=
Adjustment factor for center of tunnel pitot tube placement, Fp =
p
v
=
Dilution tunnel velocity calculated after the multi-point pitot traverse at the center, ft/sec
scent
v
=
Dilution tunnel velocity calculated after the multi-point pitot traverse, ft/sec
strav
k
=
Pitot tube constant, 85.49
p
C
=
Pitot tube coefficient: 0.99, unitless
p
ΔP*
Velocity pressure in the dilution tunnel, in H
=
Absolute average gas temperature in the dilution tunnel, °R; (°R = °F + 460)
T
=
s
P
Absolute average gas static pressure in diltuion tunnel, = P
=
s
P
=
Barometric pressure at test site, in. Hg
bar
P
Static pressure of tunnel, in. H
=
g
M
**The dilution tunnel wet molecular weight; M
=
s
Sample calculation:
13.05
Fp =
=
15.13
V
= 0.863 x 85.49 x
s
V
= 12.83 ft/s
s
*The ASTM test standard mistakenly has the square root of the average delta p instead of
the average of the square root of delta p. The current EPA Method 2 is also incorrect. This
was verified by Mike Toney at EPA.
**The ASTM test standard mistakenly identifies Ms as the dry molecular weight. It should be
the wet molecular weight as indicated in EPA Method 2.
60 of 194
Control No. P-SFDK-0002, Effective date: 5/06/2016
(
)
C
P
p
P
avg
0; (in Hg = in H
2
0.863
0.99
x
0.219 x
T
s
P
M
s
s
V
V
O
2
+ P
, in Hg
bar
g
0/13.6)
2
= 28.78 assuming a dry weight of 29 lb/lb-mole
s
93.6
+
(
(
29.90
+
60 of 194
File - Run 1, Tab - Example Calculations
strav
, ASTM E2515 Equation (1)
scent
460
1/2
)
-0.18
)
28.78
x
13.6