OMNI-Test Laboratories, Inc.
– Average particulate emissions for full integrated test run, g/hr
PM
R
ASTM E2779 equation (5)
PM
Where,
Sample Calculation:
E
(Dual train average) =
T
PM
67 of 194
Control No. P-SFDK-0002, Effective date: 5/06/2016
= 60 (E
/θ)
R
T
E
= Tota particulate emissions, grams
T
θ = Total length of full intergrated test run, min
5.28 g
θ =
361 min
= 60 x ( 5.28 / 361 )
R
PM
= 0.88
g/hr
R
67 of 194