Sherwood Meridian Series Manual page 66

Pellet-fired, freestanding or insert
Table of Contents

Advertisement

OMNI-Test Laboratories, Inc.
PR - Proportional Rate Variation
ASTM E2515 equation (16)
V
V
T
=
mi
s
m
PR
V
V
T
i
m
si
mi
Where:
θ = Total sampling time, min
θ
= Length of recording interval, min
i
= Volume of gas sample measured by the dry gas meter during the "ith"
V
mi
V
= Volume of gas sample as measured by dry gas meter, dcf
m
V
= Average gas velocity in the dilution tunnel during the "ith" time interval, ft/sec
si
V
= Average gas velocity in the dilution tunnel, ft/sec
s
= Absolute average dry gas meter temperature during the "ith" time interval,
T
mi
= Absolute average dry gas meter temperature,
T
m
= Absolute average gas temperature in the dilution tunnel during the "ith" time interval,
T
si
= Absolute average gas temperature in the dilution tunnel,
T
s
Sample calculation (for the first 1 minute interval of Train 1):
(
PR =
PR =
66 of 194
Control No. P-SFDK-0002, Effective date: 5/06/2016
T
 
si
100
T
s
time interval, dcf
361 x 0.154
x
12.83
1
x 59.52
x
13.07
96 %
o
R
x ( 114.0 + 460 ) x ( 81.9 + 460 )
x (
93.6
+ 460 ) x ( 75.0 + 460 )
66 of 194
File - Run 1, Tab - Example Calculations
o
R
o
R
)
x 100
o
R

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Meridian-1Meridian fpiMeridian cast ironGf55Gfi55

Table of Contents