Operating Instructions

Now that your Quantum Plus spa is in place, you are probably eager to take advantage of its unique designed-in features—
especially the patented Jacuzzi Whirlpool Bath hydromassage performance. Besides being a beautiful addition to your
indoor decor or outdoor landscaping, your Jacuzzi whirlpool spa will provide you with the ultimate in spa pleasure.

Basic Control Set-Up

The control set-up on your Quantum Plus spa is designed to give you fingertip control of the heater, lights, air induction,
Water Rainbow and whirlpool/filter pump and blower systems of your unit from inside or outside your spa. Follow the basic
control set-up described below to familiarize yourself with the several functions of the control panels located on the top of
the spa.
Do not turn on power to the spa unless it is filled with water to the normal water level. (See water line indicatormark
on skimmer frame.) When the power is on, the built-in timer may activate the system even though the SYSTEM is
turned off at the control panel. If the spa's motor/pump is actuated when there is not sufficient water in the unit,
the circulation pump and heater could be irreparably damaged.
spa with insufficient water could cause a fire.
Using a garden hose, fill the spa with water to the
waterline indicator mark on the skimmer frame. (See
page 20 for information on using Water Rainbow as a
fill spout if desired.)
At the house service panel, turn on the circuit breaker
or switch that controls the electrical service to your spa.
(Make sure there is no other appliance on that circuit.)
Open the skirt door giving access to the System Control
Module.
PLUG-IN
C0NNECTORS
www.clearcreekspas.com
OPERATION
CAUTION
Your spa is provided with a earth leakage circuit breaker
(ELCB). At initial start-up and at least once a month
thereafter, with power on, push the button located on
the spa System Control Module. The switch should
move to the OFF (O) position. Move the switch to the
ON (1) position to reset. If the interrupter fails to operate
in this manner, there is a ground current flowing or a
device malfunctioning, indicating the possibility of elec-
tric shock. Turn off power and do not use the spa until
the source of the breakdown has been identified and
corrected.
SYSTEM CONTROL MODULE
INTERLOCK
SWITCH
CAUTION
1. Push TEST button of GFCI.
This system is GFCI (Ground Fault Circuit Interrupter) pro-tected for your
safety. Bypassing the GFCI or tampering with the system in any way may
2. RESET button should pop out. This should cut off power
cause electrical shock, in-jury or death and will void the warranty.
GFCI
to the system. CAUTION: if RESET button does not
protection does not extend to 230 V AC circuit conversion. If test indi-cates that the GFCI
pop out, or if RESET button does pop out and system
TEMP.
is not functioning, DO NOT USE THE UNIT until the electrical
is still on, DO NOT USE YOUR SPA.
problem has been corrected. (See installation instructions.) TEST THE GFCI
3. If the GFCI tests okay, restore power by pushing in the
SAFETY
ONCE A MONTH.
reset button. The RESET button must be pushed until it locks
into place and remains depressed.
SWITCH
TEST PROCEDURE
Unit must be filled to proper water level and correct power supplied.
IF THE GFCI FAIL TO RESET PROPERLY, DO NOT USE THE
SPA! CONTACT A QUALIFIED ELECTRICIAN.
FLOW
SWITCH
LIGHT #1
Turn dial to correct time and day. Slide tabs
toward center for desired operating periods.
(One tab = 2 hrs.)
LIGHT #2
HIGH
TEMPERATURE
SAFETY
SWITCH
CAUTION:
High temperatures above the thermostat range will
OPENING DOOR VOIDS W ARRANTY
cause the high temperature safety switch to trip and
THIS EQUIPMENT REQUIRES QUALIFIED SERVICE
the system to turn off. See operating instructions.
PERSONNEL FOR PROPER REPAIR. CONTACT YOUR
When water temperature is less than 100° F., reset
JACUZZI WHIRLPOOL BATH DEALER FOR SERVICE.
by pressing the safety switch reset button located on
the cover of the heater enclosure.
NO USER SER VICABLE P ARTS BEHIND THIS DOOR.
www.clearcreekspas.com
In addition to damaging the unit, operating the
GFCI
JETS
MOT OR/
PUMP
BLOWER
HEATER
TIMER
FILTER
MOT OR/
PUMP
DO NOT BREAK DOOR SEAL;