HP LTO Ultrium Technical Reference Manual page 92

Table of Contents

Advertisement

Code
Description
2C40h
Buffer manager check buffer CRCs mismatch.
2C41h
Buffer manager check CRC passed.
2C50h
Illegal SCSI command. The hardware or firmware does not recognize the CDB.
2C51h
The SCSI Macro command was aborted because the drive was selected first.
2C52h
ATN was pulled by the initiator.
2C53h
Initiator did not respond to reselect within the reselect time-out period.
2C54h
The internal port interface task queue was empty.
2C55h
Too many port interface tasks. There is no room left in the internal port interface task queue.
2C56h
Parity error on the SCSI bus.
2C57h
Parity error in the mini-buffer.
2C58h
Attempted to use an invalid value internally.
2C59h
The SCSI FIFO was not empty when attempting to write to it.
2C5Ah
Not connected. Attempted to issue SCSI macro target command while not in target mode.
2C5Bh
Wrong host. Attempted to communicate with Host X while connected to Host Y.
2C5Ch
Wrong bus state. Attempted SCSI macro command while in the incorrect bus phase.
2C5Dh
No information on host. This host has not communicated with us previously.
2C5Eh
Invalid speed. The saved SCSI bus speed for this host is corrupt.
2C5Fh
Invalid SCSI ID, outside the range 0-15.
2C60h
The group code in CDB is not supported.
2C61h
The host attempted to issue an overlapped command.
Not enough buffer space. The internal requestor asked for more space than was available
2C62h
in the mini-buffer.
2C63h
The mini-buffer is non-functional.
2C64h
Buffer in use. The internal requestor was denied access to the mini-buffer.
2C65h
Status interrupted; the SCSI status phase failed.
2C66h
Received an IDE (Initiator Detected Error) message.
2C67h
Received an MPE (Message Parity Error) message.
2C68h
Received a BDR (Bus Device Reset) message.
2C69h
Received an Abort message.
2C6Ah
Failed the Media Information check.
92
Drive error codes