Mitsubishi Electric 800 Series Instruction Manual page 92

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Device
Internal relay (M)
Data register (D)
Link register (W)
Contact (TS)
Timer (T)
Coil (TC)
Current value (TN) Word
Contact (SS)
Retentive timer (S)
Coil (SC)
Current value (SN) Word
Contact (CS)
Counter (C)
Coil (CC)
Current value (CN) Word
*1
If write/read is requested from/to any devices outside the range, the error code H4031 is returned. (Refer to
*2
When setting the word unit of the special relay device, specify the device No. in the list of special relay as the first device No. For details of the
special relay, refer to the PLC function programming manual. Otherwise, the data is not read/written correctly.
 Link register
The following shows the link registers for parameters (read/write), inverter status monitor items (read), preventive maintenance
data (read), model information monitor items (read), and serial numbers (read).
• Parameter
Pr.
Register
For details on parameter names,
W0 to
refer to the parameter list in the FR-
0 to 999
W999
E800 Instruction Manual
(Function).
Terminal 2 frequency setting bias
C2 (902)
W902
(frequency)
Terminal 2 frequency setting bias
W4802
(analog value)
C3 (902)
Terminal 2 frequency setting bias
W4902
(terminal analog value)
Terminal 2 frequency setting gain
125 (903)
W903
(frequency)
Terminal 2 frequency setting gain
W4803
(analog value)
C4 (903)
Terminal 2 frequency setting gain
W4903
(terminal analog value)
Terminal 4 frequency setting bias
C5 (904)
W904
(frequency)
Terminal 4 frequency setting bias
W4804
(analog value)
C6 (904)
Terminal 4 frequency setting bias
W4904
(terminal analog value)
Terminal 4 frequency setting gain
126 (905)
W905
(frequency)
Terminal 4 frequency setting gain
W4805
(analog value)
C7 (905)
Terminal 4 frequency setting gain
W4905
(terminal analog value)
Terminal 4 bias (torque/magnetic
W4832
flux)
C39 (932)
Terminal 4 bias (torque/magnetic
W4932
flux) (terminal analog value)
Terminal 4 gain (torque/magnetic
W4833
flux)
C41 (933)
Terminal 4 gain (torque/magnetic
W4933
flux) (terminal analog value)
W4834
PID display bias analog value
C43 (934)
PID display bias analog value
W4934
(terminal analog value)
Category
Device code
Bit
H90
0 to 127 (decimal)
Word
HA8
0 to 255 (decimal)
Word
HB4
8192
HC1
Bit
HC0
0 to 15 (decimal)
HC2
HC7
Bit
0 (Initial value. Up to 16 retentive timers can be used by PLC
HC6
parameter assignment.)
HC8
HC4
Bit
HC3
0 to 15 (decimal)
HC5
Name
Read/write
Read/write
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read
Read/write
Read
Read/write
Read
*1
Range
page
Remarks
Analog value (%) set in C3 (902)
Analog value (%) of the voltage (current) applied to terminal
2
Analog value (%) set in C4 (903)
Analog value (%) of the voltage (current) applied to terminal
2
Analog value (%) set in C6 (904)
Analog value (%) of the current (voltage) applied to terminal
4
Analog value (%) set in C7 (905)
Analog value (%) of the current (voltage) applied to terminal
4
Analog value (%) set in C39 (932)
Analog value (%) of the current (voltage) applied to terminal
4
Analog value (%) set in C41 (933)
Analog value (%) of the current (voltage) applied to terminal
4
Analog value (%) set in C43 (934)
Analog value (%) of the current (voltage) applied to terminal
4
2. Ethernet Communication
1
2
3
4
98.)
5
6
7
8
9
10
91
2.10 SLMP