Mitsubishi Electric 800 Series Instruction Manual page 28

Communication
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

*2
Use Pr.290 to enable display of negative numbers during monitoring.
• Reply code description
The reply to the instruction execution command is set in RWr2, 10, 12, 14, 16, and 18. After the frequency setting (RYD
or RYE) or execution of instruction code (RYF), check the reply code (RWr2) in the remote register.
Data
H0000
Normal
H0001
Write mode fault
Reply code
H0002
Parameter selection fault
H0003
Setting range fault
H00
Normal
H01
Write mode fault
*1
Reply code 1
Frequency command
H03
(torque command / torque
limit) setting range error
H00
Normal
H01
Write mode fault
Reply code 2
H02
Parameter selection fault
H03
Setting range fault
*1
The contents of the reply code 1 are changed when torque commands are given or the torque is limited. The upper 4 bits of the reply code 1 are
used as the reply code to the torque command / torque limit, and the lower 4 bits are used as the reply code to the frequency command.
Bit15
Reply code2
Example) When the torque command is out of the setting range, the data is H0030.
Bit15
0
0
0
0
0
0
 Instruction code
Set instruction codes using the remote register (RWw). (Refer to
The definition read by the instruction code is stored in the remote register (RWr). (Refer to
Item
Operation mode
Item
No fault (Instruction codes are executed
without any fault.)
Parameter write is attempted when the
inverter is not in the stop status in the
Network operation mode.
Unregistered code is set.
Set data exceeds the permissible range.
No fault (Instruction codes are executed
without any fault.)
Parameter write is attempted when the
inverter is not in the stop status in the
Network operation mode.
The value outside the range is set.
No fault (Instruction codes are executed
without any fault.)
Parameter write is attempted when the
inverter is not in the stop status in the
Network operation mode.
Unregistered code is set.
Set data exceeds the permissible range.
Reply code to
the torque command /
torque limit
Reply code1
1
0
0
0
0
1
Reply code to
the torque command
Read/
Instruction
write
code
H0000: Network operation
Read
H7B
H0001: External operation, External JOG operation
H0002: PU operation, External/PU combined operation 1 or 2, PUJOG operation
H0000: Network operation
Write
HFB
H0001: External operation
H0002: PU operation (when Pr.79 = "6")
Fault description
Bit0
Reply code to
the frequency
command
Bit0
0
0
0
0
page
25.)
page
Data description
Remarks
Reply code to RWw10, 12, 14, 16, 18
Reply code to RWr2
26.)
2. Ethernet Communication
2.5 CC-Link IE TSN
1
2
3
4
5
6
7
8
9
10
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800

Table of Contents