2.11

EtherNet/IP

2.11.1 Outline

When the EtherNet/IP communication operation is performed through the Ethernet connector on the inverter, data such as
parameters, command values, and feedback values are regarded as objects used for data communication between a master
and slaves. Objects consist of the Class ID, object name, data type, access rule, etc. I/O message communication (cyclic) and
explicit message communication (acyclic) are available.
 Communication specifications
The communication specification varies depending on the specification of the master.
Item
Maximum number of
No upper limit on the same Ethernet network
branches
Ethernet cable
Connection cable
(IEEE 802.3 100BASE-TX/10BASE-T compliant cable or ANSI/TIA/EIA-568-B
(Category 5e) compliant shielded 4-pair branched cable)
 Operation status LEDs
LED name
Description
NS
Communication status
MS
Inverter status
LINK1
Connector for communication (PORT1) status
LINK2
Connector for communication (PORT2) status
 EDS file
An EDS file is available for download.
Mitsubishi Electric FA Global Website:
www.MitsubishiElectric.co.jp/fa
For details, contact your sales representative.
NOTE
• The EDS file is used in configuration software. To install the EDS file properly, refer to the instruction manual of your
configuration software.

2.11.2 Initial setting for EtherNet/IP

Use the following parameters to perform required settings for Ethernet communication between the inverter and other devices.
Description
LED status
OFF
Power-OFF / IP address not set
Blinking green
Online, no connections established
Solid green
Online, connections established
Blinking red
Connection timeout
OFF
Power-OFF / inverter reset
Blinking green
No connections established
Solid green
Operating properly
Blinking red
Warning or alarm output
Solid red
Fault detected
OFF
Power-OFF/link-down
Blinking green
Link-up (Data reception in progress)
Solid green
Link-up
OFF
Power-OFF/link-down
Blinking green
Link-up (Data reception in progress)
Solid green
Link-up