Figure 22. Load Cell Inserted Into The Load Cell Fixture - AMD Athlon 64 Thermal Design Manual

Hide thumbs Also See for Athlon 64:
Table of Contents

Advertisement

Preliminary Information
26633 Rev. 3.03 September 2003
AMD Athlon™ 64 and AMD Opteron™ Processors
Thermal Design Guide

Figure 22. Load Cell Inserted into the Load Cell Fixture

The load cell fixture should be machined from a stainless steel material. A drawing of the fixture
is shown in Figure 23 on page 43. The drawing is proportioned for the nominal dimensions of the
processor and the load cell. For the most precise measurements, a fixture should be made for each
load cell so that the overall height of the fixture and load cell is 4.37 mm.