Figure 24. Test Board With A Load Cell Fixture Installed In The Socket 754 - AMD Athlon 64 Thermal Design Manual

Hide thumbs Also See for Athlon 64:
Table of Contents

Advertisement

26633 Rev. 3.03 September 2003
A.2.2
Procedure
The following procedure details how to obtain the clip load using the load cell fixture assembly:
1. Set the voltage output on the voltage source to 15.00 V and connect the load cell as
indicated by the manufacturer.
2. With nothing touching the load cell and fixture assembly, record the zero load output
voltage in millivolts since the load measurement is based on change in voltage from no
load to the measured load.
3. Position the backplate onto the test board.
4. Place the load cell fixture in the socket.
5. Place the load cell into the fixture as shown in Figure 24.

Figure 24. Test Board with a Load Cell Fixture Installed in the Socket 754

Appendix A
Preliminary Information
AMD Athlon™ 64 and AMD Opteron™ Processors
Appendix
Thermal Design Guide
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Athlon 64 fxOpteron

Table of Contents