F F r r o o n n t t A A I I R R E E I I I I C C o o n n t t r r o o l l l l e e r r
4.
BEE386
5.
BEE387
6.
AUTO
BEE388
7.
8.
BEE390
9.
A/C
BEE389
36
Lower Value button
Higher Value button
AUTO button
DISPLAY
BEE396
SMOG button
A/C button
Lower Value button: Press the button to
decrease the desired setpoint. The minimum
is 18 °C (64 °F). For permanent cooling set LO
on the display and press A/C (9), LED A/C is
ON. For permanent ventilation set LO on
the display, LED A/C is OFF.
Higher Value button: Press the button to
increase the desired setpoint. The maximum
is 27 °C (80 °F). For permanent heating set HI
on the display.
Manual Mode: Press UP (5) and DOWN (4)
simultaneously. Use UP (5) or DOWN (4) to
set opening of the water valve (Hxxx%).
Auto Mode: The unit will heat or ventilate the
driver compartment automatically (according
to the desired setpoint and compartment
conditions), LED A/C is OFF.
Reheat/Auto Mode: The unit will cool or
heat the driver compartment automatically
(according to the desired setpoint and
compartment conditions), LED A/C is ON.
The speed of the blower will set automatically
(according to the desired setpoint and
compartment conditions).
The display shows the real time when the
system is OFF.
The display shows the required setpoint when
the system is ON.
The brightness of the display and LED's is
controlled automatically according to the
external light condition.
Recirculated Air: The fresh air damper is
closed for 10 minutes (according to the
parameter), LED is ON.
Air Condition Mode: The unit will operate in
the cool or in the reheat mode, LED is ON.
TK 53050-3-OP-EN