Specifications

APPLICATION
SETUP TEMPERATURE RANGE
OPERATING VOLTAGE RANGE
CURRENT CONSUMPTION
OPERATING TEMPERATURE RANGE
CONNECTION
DIMENSION (WxHxD)
POWER SUPPLY
INPUTS
OUTPUTS
DIAGNOSTIC / PROGRAMMING
26
Control of HVAC unit
17 °C (63 °F) to 27 °C (80 °F)
Display in °C and °F as firmware option
10 - 32 VDC
Max. 100 mA
-30 °C (-22 °F) to 80 °C (176 °F)
RS232 serial connection
CAN bus - CAN0, CAN1
187 mm x 57 mm x 60 mm
Ready for 12 VDC and 24 VDC
Interior Temperature Sensor
Freeze Temperature Sensor
Ambient Temperature Sensor
Heating Coil Temperature Sensor
Floor Heating Temperature Sensor
0 - 5 V DC Analog Input
Coil Pressure Switch
Pressure Switch (LPCO, HPCO)
(0.7 A Low Side Output - 1.0 A High Side
Output)
3 for Blower Speed - LSO - or PWM 20 kHz
Alternator Excitation - LSO
Compressor Clutch - LSO
Boost Pump - LSO
2 for Solenoid Heat Valve (PWM 0.1 Hz) -
HSO
2 for Fresh Air Damper (0 - 50 - 100% or
PWM 1 Hz) - HSO
2 LSO free (2-speed floor blower)
RS-232, CANDiag software