C C l l i i m m a a A A I I R R E E I I I I C C o o n n t t r r o o l l l l e e r r
Specifications
APPLICATION
SETUP TEMPERATURE RANGE
OPERATING VOLTAGE RANGE
CURRENT CONSUMPTION
CONNECTOR TYPE
OPERATING TEMPERATURE RANGE
COMMUNICATION
DIMMENSIONS (WxHxD)
POWER SUPPLY
DISPLAY MODULE DELUXE
ANALOG INPUT
BASE MODULE DELUXE
ANALOG INPUTS
DIGITAL INPUTS
ANALOG OUTPUTS
DIGITAL OUTPUTS
DIAGNOSTIC / PROGRAMMING
(a)
Base Module Deluxe + Display Module Deluxe; outputs are switched off.
30
(a)
Control of HVAC unit
17ºC (63ºF) to 27ºC (80ºF)
10 - 32 VDC
280 mA
Packard Metric-Pack
-40ºC (-40ºF) to 85ºC (185ºF)
CAN J1939
187 mm x 57 mm x 45 mm
Ready for 12 VDC and 24 VDC
1 Feedback Sensor
6 Temperature Sensors
6 Feedback / Temperature Sensors
6 High Side (action at 12 - 24 V)
2 Low Side (action at 0 V)
4 x 0 - 5 V
1 x 10 A; 1 x 15 A; 10 x 1 A
4 x H Bridge Output or 6 Digital outputs 250
mA
RS 232 PORT
TK 53050-3-OP-EN