System Configuration Using The Setting Menu - Pentair ControlPro Series Installation Manual

Filtration & backwash controller
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

System configuration using the SETTING menu

Before operating the system it is essential to configure the system for the components that are connected to
the system. Failure to do so can result in damage to the pool and is not taken in warranty.
As a safety measure, most of the configuration settings can only be accessed within the 'SUPERVISOR' mode.
To activate the 'SUPERVISOR' mode:
-perform a power OFF/power ON on the ControlPro
-From the startup screen, push
displayed. The supervisor access will be maintained for 15 minutes.
The 'SUPERVISOR' menu options are marked with a light background is this manual
Clock setting
10:10
Date setting
13/02/2015
Language
English
Event
Log
Multi-Speed Pump
Yes/No
Heating Device
Solar
PRO VALVE
Yes/No
Heat/Antifreeze
Yes/No
Filter when open
No
Minimum Temp.
12.0°C
Display Nr
1
Factory Reset
** These menus or screens are only accessible from within the SUPERVISOR menu. In this manual they are
represented with a lighter background.
14
ControlPro
ESC
ENT
and
This screen allows changing the time settings. Pushing
the 'Hour' setting (the 'Hour' value will blink).
+
-
Use
or
to adjust. Use
'Minute' setting and use the same procedure to change
Similar to the previous screen this screen allows for adjusting the date value.
Control pro can be set up in 6 different languages: English French(default),,
German, Dutch, Spanish or Italian. Pushing
'Language' setting (the 'Language' value will blink).
+
-
Use
or
to adjust. Use
** This menu gives access to 4 extra information screens using
1. Event log shows type and date for last alarm
2. Commissioning indicates date of first use of the system
3. Last anti frost
4. Last backwash
This info can be useful for troubleshooting
**Set this menu to YES if you are using a variable speed pump. Keep NO is the
installed pump is a single speed pump.
**Determines if the system is used with a heating system. The options are:
NO
=no heater connected
SOLAR = solar heating (requires 3way valve and extra temperature sensor)
HEATER = heat pump or other type of heater connected to 'heater output'
HEATER + SOLAR = both heating and solar outputs are used.
**Determines if a ProValve backwash valve is connected
**Determines if heater output becomes active in antifreeze mode
** It is possible to have the filtration active whenever the pool cover is open
(requires connection to the 'pool cover' input) Select 'NO' if this is not
required. Select 'YES' or in case of a multispeed pump one of the 4 speeds
(V1,V2,V3,V4) to run the pump whenever the pool cover is open and the
filtration is not 'OFF'.
**Below the indicated temperature the 'dosing' output will be disabled. This
temperature can be changed using ENT. Use
ENT
to confirm.
** Shows the display number (1 or 2)
** Allows for a factory reset of all data and settings. Use
simultaneously for 10 sec. 'SUPERVISOR' will be
ENT
to confirm and move to the
ENT
ENT
to confirm
+
ENT
will activate
will activate the
ENT
-
or
to adjust. Use
ENT
to confirm.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Controlpro cpro-1010

Table of Contents