Service

8 Service menu
The Service menu allows performing the maintenance tasks described below.
8.2 Walk test
Walk test
in progress
Walk test allows the user to test all detectors in the selected areas.
To perform the walk test:
1. Enter the menu.
Next, you are prompted to choose between total and reduced walk test.
Walktest scope
>Total<
The following options are available:
- Total: Standard walk test. All appropriate zones are tested.
- Reduced: Reduced walk test. This test is limited only zones that were not
active recently, during last 4 hours, or since the last set.
Choose a walk test scope and press Enter.
The display lists all zones to be tested.
1>Zone 1
Need Active
2. Walk along all detection points and make sure the detector is activated either
by walking in front of it or by opening a door or window.
Each activated zone is removed from the list on the display.
3. Return to the keypad and verify the result.
If the test is passed, the following message is displayed:
Walk test OK
Press Enter
Otherwise, there still is a list of untested zones. Contact the installer if you are
unable to pass the walk test.
See also "Performing a walk test" on page 15 for more information.
8.5 Communications