WAGNER Model 9140 Owner's Manual page 11

High performance airless sprayer
Table of Contents

Advertisement

Available languages

Available languages

C
S
LEANING THE
PRAY
1. Make sure the pump is switched OFF (O), the
PRIME/SPRAY knob is turned to PRIME, and unplug the
sprayer.
2. Remove spray gun from the paint hose using adjustable
wrenches.
3. Remove filter from spray gun (refer to Cleaning the
Spray Gun Filter, page 9).
Housing
Filter
GX-06/07
Spring
Fitting
4. Remove spray tip from spray guard assembly.
Continue cleaning instructions on next column
© 2003 Wagner Spray Tech - All rights reserved.
C
(
LEANUP
CONTINUED
G
F
T
UN
ILTER AND
GX-08/10
Filter
Trigger
guard
Housing
11
)
A
IP
SSEMBLY
5 Clean spray tip and filter with a soft-bristled brush and the
appropriate cleaning solution. Be sure to remove and
clean the washer and saddle seat located in the rear of
the spray tip assembly.
Saddle
Washer
seat
6. Reassemble spray gun:
• install gun filter tapered-end first, and
Housing
Filter
GX-06/07
Spring
Fitting
• install spray tip, saddle seat and washer, and replace
spray guard assembly.
7. Thread the spray gun back onto the paint hose. Tighten
with a wrench.
IMPORTANT!
If you used oil-based paints, you must flush the pump
again using warm, soapy water to prepare it for
storage. Repeat Cleaning the Suction Set instructions.
Customer Service: 800-880-0993