2. TC : Total capacity(kW), SHC : Sensible Heating Capacity(kW)
3. PI : Power Input (kW, Compressor + indoor fan motor + outdoor fan motor)
4. All capacities are net. A deduction (cooling mode) or an addition (heating mode) of Capacity due to operating heat of indoor unit motor is reflected.
5. Direct interpolation is permissible. Do not extrapolate.
6. Rated capacities and power inputs are based on standard temperature and piping conditions, and it can be found on specifications table. Except for
rated value, the performance is not guaranteed.
7. In accordance with the test standard(or nations), the rating will vary slightly.
Correction factor due to the indoor unit combination
Cooling
ATNH12GRLE2[CT12 NR2]
Indoor Unit
TC
Max.
1.10
Rated
1.00
Heating
ATNH12GRLE2[CT12 NR2]
Indoor Unit
TC
Max.
1.10
Rated
1.00
Note
Except for standard temperature condition, the capacity is not guaranteed.