LG AUUW09GA0 Engineering Product Data Book page 142

Table of Contents

Advertisement

Single CAC
Outdoor Unit
10. Sound Levels
10.1 Sound Pressure Levels
Overall
1m
AUUW18GC0 [UU18WC UL0]
AUUW24GC0 [UU24WC UE0]
AUUW30GC0 [UU30WC UE0]
AUUW36GC0 [UU36WC U40]
AUUW18GC0 [UU18WC UL0]
80
70
60
50
40
30
20
Approximate
Hearing
Threshold
10
63
125
250
500
Octave Band Center Frequency (Hz)
22
1.5m
Model
AUUW24GC0 [UU24WC UE0]
80
▲ Cooling
Heating
70
NC-65
60
NC-60
NC-55
50
NC-50
NC-45
40
NC-40
NC-35
30
NC-30
NC-25
20
Approximate
NC-20
Hearing
Threshold
NC-15
10
1000
2000 4000
8000
Note
1.Data is valid at free field condition.
2.Reference accoustic pressure 0dB = 20μPa.
3.Data is valid at nominal operation condition.
Refer to the Model Specifications for nominal
conditions(Power source and Ambient temperature, etc)
4.Sound levels can be increased in accordance with
installation and operating conditions. (Operating conditions
include some functional condition like Static pressure
mode, air guide use, Room target temperature setting, etc
and these functions are different in accordance with each
model.)
5.Sound level will vary depending on a range of factors such
as the construction(acoustic absorption coefficient) of
particular room in which the equipment in installed.
Sound Pressure Levels [dB(A)]
Cooling
47
48
51
54
▲ Cooling
Heating
NC-65
NC-60
NC-55
NC-50
NC-45
NC-40
NC-35
NC-30
NC-25
NC-20
NC-15
63
125
250
500
1000
2000 4000
8000
Octave Band Center Frequency (Hz)
Compact Inverter
Heating
49
50
52
56
AUUW30GC0 [UU30WC UE0]
80
▲ Cooling
Heating
70
60
50
40
30
20
Approximate
Hearing
Threshold
10
63
125
250
500
1000
2000 4000
Octave Band Center Frequency (Hz)
NC-65
NC-60
NC-55
NC-50
NC-45
NC-40
NC-35
NC-30
NC-25
NC-20
NC-15
8000

Hide quick links: