LG AUUW09GA0 Engineering Product Data Book page 141

Table of Contents

Advertisement

Single CAC
Outdoor Unit
9. Electric Characteristics
Combined Indoor Unit
Outdoor Unit
Model names
Model names
AUUW18GC0
ABNW18GBHC0
[UU18WC UL0]
[UB18C NH0]
AUUW24GC0
ABNW24GBHC0
[UU24WC UE0]
[UB24C NH0]
AUUW30GC0
ABNW30GM1A0
[UU30WC UE0]
[UM30 N14]
AUUW36GC0
ABNW36GM2A0
[UU36WC U40]
[UM36 N24]
Note
1. Voltage supplied to the unit terminals should be within the minimum and maximum
range.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MSC means the Max. current during the starting of compressor.
4. MSC and RLA are measured as the compressor only test condition.
5. OFM and IFM are measured as the outdoor unit test condition.
6. Select the wire size based on the MCA.
7. MFA is used to select the circuit breaker and ground fault circuit interrupter, and
recommended circuit breaker type is ELCB(Earth Leakage Circuit Breaker).
Unit
No. of
Pha
Voltager
Hz
Volts
Units
se
Min.:198
220 -
1
50
240
Max.:264
Power Supply
COMP
MFA
MCA
MSC RLA
ange
(MOP)
12.6
15
-
17.9
20
-
18.4
20
-
21.2
25
-
MCA : Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes (A)
MSC : Maximum Starting Current
RLA : Rated Load Amperes (A)
OFM : Outdoor Fan Motor
IFM : Indoor Fan Motor
kW : Fan Motor rated output (kW)
FLA : Full Load Amperes (A)
Compact Inverter
OFM
IFM
kW
FLA
kW
10.0
0.043
0.25
0.154
15.0
0.085
0.33
0.154
15.0
0.085
0.33
0.137
17.0
0.124
0.48
0.350
FLA
0.80
1.10
0.80
1.14
21