Advertisement

Heat Pump 50Hz/410A
5CSL0-02C(Replaces:5CSL0-02B)
P/No. : MFL67502810

Advertisement

Table of Contents
loading

Summary of Contents for LG AUUW09GA0

  • Page 1 Heat Pump 50Hz/410A 5CSL0-02C(Replaces:5CSL0-02B) P/No. : MFL67502810...
  • Page 2 Single CAC Outdoor Unit General Information Product Data Standard Inverter Standard Inverter - Synchro Compact Inverter Installation of Outdoor Units...
  • Page 3 Outdoor Unit General Information Single CAC 1.Model Line Up 2.Nomenclature...
  • Page 4 Single CAC Outdoor Unit General Information 1. Model Line Up 1.1 Standard Inverter 1 Phase Inverter AUUW09GA0 AUUW12GA0 AUUW18GAE Model Names [UU09W UL0] [UU12W UL0] [UU18W UE4] No. of connectable indoor units Total capacity index of connectable indoor units(kW) Power supply 1Ø, 220 - 240V, 50Hz...
  • Page 5: Model Line Up

    Single CAC Outdoor Unit General Information 1. Model Line Up 3 Phase Inverter AUUW368D2 Model Names [UU37W UO2] No. of connectable indoor units Total capacity index of 10.0 connectable indoor units(kW) Power supply 3Ø, 380 - 415V, 50Hz External Appearance AUUW428D2 AUUW488D2 AUUW608D2...
  • Page 6 Single CAC Outdoor Unit General Information 1. Model Line Up 1.2 Compact Inverter AUUW18GC0 AUUW24GC0 Model Names [UU18WC UL0] [UU24WC UE0] No. of connectable indoor units Nominal Capacity (kW) Power supply 1Ø, 220 - 240V, 50Hz External Appearance AUUW30GC0 AUUW36GC0 Model Names [UU30WC UE0] [UU36WC U40]...
  • Page 7 Single CAC Outdoor Unit General Information 2. Nomenclature 2.1 Outdoor units(Global) Model Name Signification Indicates that this is a R410A SINGLE A outdoor unit Model type C : Cooling Only, H : Heat Pump, W: Inverter Heat Pump Capacity Code based on ‘kBtu/h’ units Electrical rating 6:1Ø,220V-240V,50 Hz 8:3Ø,380V-415V,50 Hz...
  • Page 8 Outdoor Unit Product Data Single CAC Standard Inverter Standard Inverter - Synchro Compact Inverter...
  • Page 9 Outdoor Unit Standard Inverter Single CAC 1.List of Functions 2.Specifications 3.Dimensions 4.Piping Diagrams 5.Wiring Diagrams 6.Capacity Tables 7.Capacity Coefficient Factor 8.Operation Range 9.Electric Characteristics 10.Sound Levels...
  • Page 10: List Of Functions

    Single CAC Outdoor Unit Standard Inverter 1. List of Functions 1 Phase Inverter AUUW09GA0 AUUW12GA0 AUUW18GAE Category Functions [UU09W UL0] [UU12W UL0] [UU18W UE4] Defrost / Deicing High pressure switch Low pressure switch Reliability Phase protection Restart delay (3-minutes) Self diagnosis...
  • Page 11 Single CAC Outdoor Unit Standard Inverter 1. List of Functions AUUW24GAE AUUW30GAE AUUW366D2 Category Functions [UU24W U44] [UU30W U44] [UU36W UO2] Defrost / Deicing High pressure switch Low pressure switch Reliability Phase protection Restart delay (3-minutes) Self diagnosis Soft start Test function Night Silent Operation Peak Control...
  • Page 12 Single CAC Outdoor Unit Standard Inverter 1. List of Functions AUUW426D2 AUUW486D2 AUUW606D2 Category Functions [UU42W U32] [UU48W U32] [UU60W U32] Defrost / Deicing High pressure switch Low pressure switch Reliability Phase protection Restart delay (3-minutes) Self diagnosis Soft start Test function Night Silent Operation Peak Control...
  • Page 13 Single CAC Outdoor Unit Standard Inverter 1. List of Functions 3 Phase Inverter AUUW368D2 AUUW428D2 AUUW488D2 Category Functions [UU37W UO2] [UU43W U32] [UU49W U32] Defrost / Deicing High pressure switch Low pressure switch Reliability Phase protection Restart delay (3-minutes) Self diagnosis Soft start Test function Night Silent Operation...
  • Page 14 Single CAC Outdoor Unit Standard Inverter 1. List of Functions AUUW608D2 AUUW70LAE AUUW85LAE Category Functions [UU61W U32] [UU70W U34] [UU85W U74] Defrost / Deicing High pressure switch Low pressure switch Reliability Phase protection Restart delay (3-minutes) Self diagnosis Soft start Test function Night Silent Operation Peak Control...
  • Page 15: Specifications

    Single CAC Outdoor Unit Standard Inverter 2. Specifications Combinational Specifiactions  1 Phase Inverter AUUW09GA0 AUUW09GA0 Outdoor unit [UU09W UL0] [UU09W UL0] Combination ATNH09GRLE2 ABNW09GL2A2 Indoor unit [CT09 NR2] [CB09L N22] Min.~Rated~Max. 1.00 ~ 2.50 ~ 2.75 1.10 ~ 2.50 ~ 2.90 Cooling Min.~Rated~Max.
  • Page 16 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW12GA0 AUUW12GA0 Outdoor unit [UU12W UL0] [UU12W UL0] Combination ATNH12GRLE2 ABNH12GL2A2 Indoor unit [CT12 NR2] [CB12L N22] Min.~Rated~Max. 1.36 ~ 3.40 ~ 3.74 1.40 ~ 3.40 ~ 3.70 Cooling Min.~Rated~Max. Btu/h 4,600 ~ 11,600 ~ 12,800 4,800 ~ 11,600 ~ 12,600 Capacity Min.~Rated~Max.
  • Page 17 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW18GAE AUUW18GAE Outdoor unit [UU18W UE4] [UU18W UE4] Combination ATNW18GQLA0 ABNW18GM1A0 Indoor unit [CT18 NQ4] [CM18 N14] Min.~Rated~Max. 2.00 ~ 5.00 ~ 5.50 1.80 ~ 5.00 ~ 6.00 Cooling Min.~Rated~Max. Btu/h 6,800 ~ 17,100 ~ 18,700 6,100 ~ 17,100 ~ 20,500 Capacity Min.~Rated~Max.
  • Page 18 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW24GAE AUUW24GAE Outdoor unit [UU24W U44] [UU24W U44] Combination ATNW24GPLA0 ABNW24GM1A0 Indoor unit [CT24 NP4] [CM24 N14] Min.~Rated~Max. 2.84 ~ 6.80 ~ 7.80 2.80 ~ 6.80 ~ 7.48 Cooling Min.~Rated~Max. Btu/h 9,700 ~ 23,200 ~ 26,600 9,500 ~ 23,200 ~ 25,500 Capacity Min.~Rated~Max.
  • Page 19 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW30GAE AUUW30GAE Outdoor unit [UU30W U44] [UU30W U44] Combination ATNW30GPLA0 ABNW30GM1A0 Indoor unit [UT30 NP4] [UM30 N14] Min.~Rated~Max. 3.20 ~ 8.00 ~ 8.80 3.20 ~ 7.80 ~ 8.80 Cooling Min.~Rated~Max. Btu/h 10,900 ~ 27,300 ~ 30,000 10,900 ~ 26,600 ~ 30,000 Capacity Min.~Rated~Max.
  • Page 20 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW366D2 AUUW366D2 Outdoor unit [UU36W UO2] [UU36W UO2] Combination ATNH36GNLE2 ABNW36GM2A0 Indoor unit [UT36 NN2] [UM36 N24] Min.~Rated~Max. 4.00 ~ 10.0 ~ 11.0 4.00 ~ 10.0 ~ 11.0 Cooling Min.~Rated~Max. Btu/h 13,600 ~ 34,100 ~ 37,500 13,600 ~ 34,100 ~ 37,500 Capacity Min.~Rated~Max.
  • Page 21 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW426D2 AUUW426D2 Outdoor unit [UU42W U32] [UU42W U32] Combination ATNH42GMLE2 ABNW42GM2A0 Indoor unit [UT42 NM2] [UM42 N24] Min.~Rated~Max. 5.00 ~ 12.5 ~ 13.8 5.00 ~ 12.1 ~ 13.2 Cooling Min.~Rated~Max. Btu/h 17,100 ~ 42,700 ~ 47,100 17,100 ~ 41,300 ~ 45,000 Capacity Min.~Rated~Max.
  • Page 22 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW486D2 AUUW486D2 Outdoor unit [UU48W U32] [UU48W U32] Combination ATNH48GMLE2 ABNW48GM3A0 Indoor unit [UT48 NM2] [UM48 N34] Min.~Rated~Max. 5.48 ~ 13.9 ~ 15.7 5.60 ~ 14.0 ~ 15.4 Cooling Min.~Rated~Max. Btu/h 18,700 ~ 47,400 ~ 53,600 19,100 ~ 47,800 ~ 52,600 Capacity Min.~Rated~Max.
  • Page 23 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW606D2 AUUW606D2 Outdoor unit [UU60W U32] [UU60W U32] Combination ATNH60GMLE2 ABNW60GM3A0 Indoor unit [UT60 NM2] [UM60 N34] Min.~Rated~Max. 5.92 ~ 14.6 ~ 16.3 5.90 ~ 15.0 ~ 16.3 Cooling Min.~Rated~Max. Btu/h 20,200 ~ 49,800 ~ 55,600 20,100 ~ 51,200 ~ 55,600 Capacity Min.~Rated~Max.
  • Page 24 Single CAC Outdoor Unit Standard Inverter 2. Specifications  3 Phase Inverter AUUW368D2 AUUW368D2 Outdoor unit [UU37W UO2] [UU37W UO2] Combination ATNH36GNLE2 ABNW36GM2A0 Indoor unit [UT36 NN2] [UM36 N24] Min.~Rated~Max. 4.00 ~ 10.0 ~ 11.0 4.00 ~ 10.0 ~ 11.0 Cooling Min.~Rated~Max.
  • Page 25 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW428D2 AUUW428D2 Outdoor unit [UU43W U32] [UU43W U32] Combination ATNH42GMLE2 ABNW42GM2A0 Indoor unit [UT42 NM2] [UM42 N24] Min.~Rated~Max. 5.00 ~ 12.5 ~ 13.8 5.00 ~ 12.1 ~ 13.2 Cooling Min.~Rated~Max. Btu/h 17,100 ~ 42,700 ~ 47,100 17,100 ~ 41,300 ~ 45,000 Capacity Min.~Rated~Max.
  • Page 26 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW488D2 AUUW488D2 Outdoor unit [UU49W U32] [UU49W U32] Combination ATNH48GMLE2 ABNW48GM3A0 Indoor unit [UT48 NM2] [UM48 N34] Min.~Rated~Max. 5.48 ~ 13.9 ~ 15.7 5.60 ~ 14.0 ~ 15.4 Cooling Min.~Rated~Max. Btu/h 18,700 ~ 47,400 ~ 53,600 19,100 ~ 47,800 ~ 52,600 Capacity Min.~Rated~Max.
  • Page 27 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW608D2 AUUW608D2 Outdoor unit [UU61W U32] [UU61W U32] Combination ATNH60GMLE2 ABNW60GM3A0 Indoor unit [UT60 NM2] [UM60 N34] Min.~Rated~Max. 5.92 ~ 14.6 ~ 16.3 5.90 ~ 15.0 ~ 16.3 Cooling Min.~Rated~Max. Btu/h 20,200 ~ 49,800 ~ 55,600 20,100 ~ 51,200 ~ 55,600 Capacity Min.~Rated~Max.
  • Page 28 Single CAC Outdoor Unit Standard Inverter 2. Specifications Outdoor Unit Specifiactions  1 Phase Inverter AUUW09GA0 AUUW12GA0 Outdoor unit [UU09W UL0] [UU12W UL0] Power Supply V , Ø , Hz 220-240, 1, 50 220-240, 1, 50 No. × mm² Power Supply Cable Wiring Connections 3C ×...
  • Page 29 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW18GAE AUUW24GAE Outdoor unit [UU18W UE4] [UU24W U44] Power Supply V , Ø , Hz 220-240 / 1 / 50 220-240 / 1 / 50 No. × mm² Power Supply Cable Wiring Connections 3C ×...
  • Page 30 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW30GAE AUUW366D2 Outdoor unit [UU30W U44] [UU36W UO2] Power Supply V , Ø , Hz 220-240, 1, 50 220-240, 1, 50 No. × mm² Power Supply Cable Wiring Connections 3C × 2.5 (12) 3C ×...
  • Page 31 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW426D2 AUUW486D2 Outdoor unit [UU42W U32] [UU48W U32] Power Supply V , Ø , Hz 220-240, 1, 50 220-240, 1, 50 No. × mm² Power Supply Cable Wiring Connections 3C × 5.0 (8) 3C ×...
  • Page 32 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW606D2 Outdoor unit [UU60W U32] Power Supply V , Ø , Hz 220-240, 1, 50 No. × mm² Power Supply Cable Wiring Connections 3C × 5.0 (8) (included Earth) (AWG) Casing Color Warm Gray Dimensions W ×...
  • Page 33 Single CAC Outdoor Unit Standard Inverter 2. Specifications  3 Phase Inverter AUUW368D2 AUUW428D2 Outdoor unit [UU37W UO2] [UU43W U32] Power Supply V , Ø , Hz 380-415, 3, 50 380-415, 3, 50 No. × mm² Power Supply Cable Wiring Connections 5C ×...
  • Page 34 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW488D2 AUUW608D2 Outdoor unit [UU49W U32] [UU61W U32] Power Supply V , Ø , Hz 380-415, 3, 50 380-415, 3, 50 No. × mm² Power Supply Cable Wiring Connections 5C × 2.5 (12) 5C ×...
  • Page 35 Single CAC Outdoor Unit Standard Inverter 2. Specifications AUUW70LAE AUUW85LAE Outdoor unit [UU70W U34] [UU85W U74] Power Supply V , Ø , Hz 380-415, 3, 50 380-415, 3, 50 Power Supply Cable No. × mm² Wiring Connections 5C × 2.5 (12) 5C ×...
  • Page 36 Single CAC Outdoor Unit Standard Inverter 3. Dimensions AUUW09GA0 [UU09W UL0] / AUUW12GA0 [UU12W UL0]...
  • Page 37 Single CAC Outdoor Unit Standard Inverter 3. Dimensions AUUW 18GAE [UU18W UE4]...
  • Page 38 Single CAC Outdoor Unit Standard Inverter 3. Dimensions AUUW24GAE [UU24W U44] / AUUW30GAE [UU30W U44]...
  • Page 39 Single CAC Outdoor Unit Standard Inverter 3. Dimensions AUUW366D2 [UU36W UO2] / AUUW368D2 [UU37W UO2]...
  • Page 40 Single CAC Outdoor Unit Standard Inverter 3. Dimensions AUUW426D2 [UU42W U32] / AUUW486D2 [UU48W U32] / AUUW606D2 [UU60W U32] AUUW428D2 [UU43W U32] / AUUW488D2 [UU49W U32] / AUUW608D2 [UU61W U32] AUUW70LAE [UU70W U34]...
  • Page 41 Single CAC Outdoor Unit Standard Inverter 3. Dimensions AUUW85LAE [UU85W U74]...
  • Page 42: Piping Diagrams

    Single CAC Outdoor Unit Standard Inverter 4. Piping Diagrams AUUW09GA0 [UU09W UL0], AUUW12GA0 [UU12W UL0] Outdoor Unit Inlet Air Temperature Refrigerant Flow Condenser Out Thermistor Temperature Thermistor Cooling Heating Condensing Temperature Thermistor Flare Connection Electronic Expansion Strainer Strainer Valve Liquid Side...
  • Page 43 Single CAC Outdoor Unit Standard Inverter 4. Piping Diagrams AUUW18GAE [UU18W UE4], AUUW24GAE [UU24W U44], AUUW30GAE [UU30W U44] Outdoor Unit Inlet Air Temperature Refrigerant Flow Condenser Out Thermistor Temperature Thermistor Cooling Heating Condensing Temperature Thermistor Flare Connection Electronic Expansion Strainer Strainer Valve Liquid Side...
  • Page 44 Single CAC Outdoor Unit Standard Inverter 4. Piping Diagrams AUUW366D2 [UU36W UO2] Outdoor Unit Inlet Air Temperature Condenser Out Refrigerant Flow Temperature Thermistor Thermistor Cooling Heating Condensing Temperature Thermistor Ø9.52 Flare Connection Electronic Strainer Strainer Expansion Valve Liquid Side Piping Capillary Tube Pressure...
  • Page 45 Single CAC Outdoor Unit Standard Inverter 4. Piping Diagrams AUUW368D2 [UU37W UO2] Outdoor Unit Inlet Air Temperature Condenser Out Refrigerant Flow Temperature Thermistor Thermistor Cooling Heating Condensing Temperature Thermistor Ø9.52 Flare Connection Electronic Strainer Strainer Expansion Valve Liquid Side Piping Capillary Tube Pressure...
  • Page 46 Single CAC Outdoor Unit Standard Inverter 4. Piping Diagrams AUUW426D2 [UU42W U32], AUUW486D2 [UU48W U32], AUUW606D2 [UU60W U32] Outdoor Unit Inlet Air Temperature Refrigerant Flow Condenser Out Thermistor Temperature Thermistor Cooling Heating Condensing Temperature Thermistor Flare Connection Strainer Strainer Liquid Side Piping Electronic Expansion Valve...
  • Page 47 Single CAC Outdoor Unit Standard Inverter 4. Piping Diagrams AUUW428D2 [UU43W U32], AUUW488D2 [UU49W U32], AUUW608D2 [UU61W U32] Outdoor Unit Inlet Air Temperature Refrigerant Flow Condenser Out Thermistor Temperature Thermistor Cooling Heating Condensing Temperature Thermistor Ø9.52 Flare Connection Strainer Strainer Liquid Side Piping Electronic...
  • Page 48 Single CAC Outdoor Unit Standard Inverter 4. Piping Diagrams AUUW70LAE [UU70W U34] Outdoor Unit Inlet Air Temperature Condenser Out Thermistor Temperature Thermistor Condensing Temperature Thermistor Ø9.52 Welding Connection Strainer Strainer Liquid Side Piping Electronic Expansion Valve Gas Side Pressure Piping 4 way Sensor Valve...
  • Page 49 Single CAC Outdoor Unit Standard Inverter 4. Piping Diagrams AUUW85LAE [UU85W U74] Outdoor Unit Inlet Air Temperature Condenser Out Thermistor Temperature Thermistor Condensing Temperature Thermistor Ø12.7 Welding Connection Strainer Strainer Liquid Side Piping Electronic Expansion Valve Gas Side Pressure Piping 4 way Sensor Valve...
  • Page 50: Wiring Diagrams

    Single CAC Outdoor Unit Standard Inverter 5. Wiring Diagrams AUUW09GA0 [UU09W UL0], AUUW12GA0 [UU12W UL0]...
  • Page 51 Single CAC Outdoor Unit Standard Inverter 5. Wiring Diagrams AUUW18GAE [UU18W UE4]...
  • Page 52 Single CAC Outdoor Unit Standard Inverter 5. Wiring Diagrams AUUW24GAE [UU24W U44] , AUUW30GAE [UU30W U44]...
  • Page 53 Single CAC Outdoor Unit Standard Inverter 5. Wiring Diagrams AUUW366D2 [UU36W UO2]...
  • Page 54 Single CAC Outdoor Unit Standard Inverter 5. Wiring Diagrams AUUW426D2 [UU42W U32], AUUW486D2 [UU48W U32], AUUW606D2 [UU60W U32]...
  • Page 55 Single CAC Outdoor Unit Standard Inverter 5. Wiring Diagrams AUUW368D2 [UU37W UO2]...
  • Page 56 Single CAC Outdoor Unit Standard Inverter 5. Wiring Diagrams AUUW428D2 [UU43W U32], AUUW488D2 [UU49W U32], AUUW608D2 [UU61W U32]...
  • Page 57 Single CAC Outdoor Unit Standard Inverter 5. Wiring Diagrams AUUW70LAE [UU70W U34]...
  • Page 58 Single CAC Outdoor Unit Standard Inverter 5. Wiring Diagrams AUUW85LAE [UU85W U74]...
  • Page 59: Cooling Capacity

    Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.1 AUUW09GA0 [UU09W UL0] Cooling Capacity Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0...
  • Page 60 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.2 AUUW12GA0 [UU12W UL0] Cooling Capacity Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB 20.0...
  • Page 61 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.3 AUUW18GAE [UU18W UE4] Cooling Capacity Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB 20.0...
  • Page 62 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.4 AUU24GAE [UU24W U44] Cooling Capacity Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB 20.0...
  • Page 63 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.5 AUUW30GAE [UU30W U44] Cooling Capacity Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB 20.0...
  • Page 64 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.6 AUUW366D2 [UU36W UO2] Cooing Capacity  ATNH36GNLE2 [UT36 NN2] Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB...
  • Page 65 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables Heating Capacity  ATNH36GNLE2 [UT36 NN2] Indoor Air Temperature : °CDB Outdoor Air Temp. 16.0 18.0 20.0 21.0 22.0 24.0 °CWB -15.0 8.61 5.19 8.53 5.26 8.47 5.36 8.45 5.40 8.43 5.47 8.35 5.56...
  • Page 66 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.7 AUUW426D2 [UU41W U32] Cooling Capacity  ATNH42GMLE2 [UT42 NM2] Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB...
  • Page 67 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables  1Ø Synchro Equlvalent capacity table Max Power input of each model is tabulated below (Duo) Model CT24 NP2(4) * 2 CM24 N14 * 2 CV24 NJ2 * 2 CB24L N32 * 2 4.60 4.60 4.60...
  • Page 68 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables Heating Capacity  ATNH42GMLE2 [UT42 NM2] Indoor Air Temperature : °CDB Outdoor Air Temp. 16.0 18.0 20.0 21.0 22.0 24.0 °CWB -15.0 10.96 6.21 10.86 6.31 10.78 6.42 10.75 6.48 10.73 6.55 10.63 6.66...
  • Page 69 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables  1Ø Synchro Equlvalent capacity table Max Power Input of each model is tabulated below (Duo) Model CT24 NP2(4) * 2 CM24 N14 * 2 CV24 NJ2 * 2 CB24L N32 * 2 4.60 4.60 4.60...
  • Page 70 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.8 AUUW486D2 [UU48W U32] Cooling Capacity  ATNH48GMLE2 [UT48 NM2] Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB...
  • Page 71 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables  1Ø Synchro Equlvalent capacity table Max Power Input of each model is tabulated below (Duo) Model CT24 NP2(4) * 2 CM24 N14 * 2 CV24 NJ2 * 2 CB24L N32 * 2 5.06 5.06 5.06...
  • Page 72 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables Heating Capacity  ATNH48GMLE2 [UT48 NM2] Indoor Air Temperature : °CDB Outdoor Air Temp. 16.0 18.0 20.0 21.0 22.0 24.0 °CWB -15.0 12.52 7.29 12.41 7.40 12.32 7.53 12.29 7.60 12.27 7.68 12.15 7.81...
  • Page 73 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables  1Ø Synchro Equlvalent capacity table Max Power Input of each model is tabulated below (Duo) Model CT24 NP2(4) * 2 CM24 N14 * 2 CV24 NJ2 * 2 CB24L N32 * 2 5.06 5.06 5.06...
  • Page 74 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.9 AUUW606D2 [UU60W U32] Cooling Capacity  ATNH60GMLE2 [UT60 NM2] Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB...
  • Page 75 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables  1Ø Synchro Equlvalent capacity table Max Power Input of each model is tabulated below (Duo) Model UT30 NP2(4) * 2 UM30 N14 * 2 UV30 NJ2 * 2 5.80 5.80 5.80 (Trio) Model...
  • Page 76 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables Heating Capacity  ATNH60GMLE2 [UT60 NM2] Indoor Air Temperature : °CDB Outdoor Air Temp. 16.0 18.0 20.0 21.0 22.0 24.0 °CWB -15.0 13.31 8.83 13.18 8.96 13.09 9.12 13.06 9.20 13.03 9.31 12.91 9.47...
  • Page 77 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables  1Ø Synchro Equlvalent capacity table Max Power Input of each model is tabulated below (Duo) Model UT30 NP2(4) * 2 UM30 N14 * 2 UV30 NJ2 * 2 5.70 5.70 5.70 (Trio) Model...
  • Page 78 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.10 AUUW368D2 [UU37W UO2] Cooling Capacity  ATNH36GNLE2 [UT36 NN2] Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB...
  • Page 79 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables Heating Capacity  ATNH36GNLE2 [UT36 NN2] Indoor Air Temperature : °CDB Outdoor Air Temp. 16.0 18.0 20.0 21.0 22.0 24.0 °CWB -15.0 8.61 5.19 8.53 5.26 8.47 5.36 8.45 5.40 8.43 5.47 8.35 5.56...
  • Page 80 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.11 AUUW428D2 [UU43W U32] Cooling Capacity  ATNH42GMLE2 [UT42 NM2] Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB...
  • Page 81 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables  3Ø Synchro Equlvalent capacity table Max Power Input of each model is tabulated below (Duo) Model CT24 NP2(4) * 2 CM24 N14 * 2 CV24 NJ2 * 2 CB24L N32 * 2 4.60 4.60 4.60...
  • Page 82 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables Heating Capacity  ATNH42GMLE2 [UT42 NM2] Indoor Air Temperature : °CDB Outdoor Air Temp. 16.0 18.0 20.0 21.0 22.0 24.0 °CWB -15.0 10.96 6.21 10.86 6.31 10.78 6.42 10.75 6.48 10.73 6.55 10.63 6.66...
  • Page 83 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables  3Ø Synchro Equlvalent capacity table Max Power Input of each model is tabulated below (Duo) Model CT24 NP2(4) * 2 CM24 N14 * 2 CV24 NJ2 * 2 CB24L N32 * 2 4.60 4.60 4.60...
  • Page 84 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.12 AUUW488D2 [UU49W U32] Cooling Capacity  ATNH48GMLE2 [UT48 NM2] Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB...
  • Page 85 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables  3Ø Synchro Equlvalent capacity table Max Power Input of each model is tabulated below (Duo) Model CT24 NP2(4) * 2 CM24 N14 * 2 CV24 NJ2 * 2 CB24L N32 * 2 5.06 5.06 5.06...
  • Page 86 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables Heating Capacity  ATNH48GMLE2 [UT48 NM2] Indoor Air Temperature : °CDB Outdoor Air Temp. 16.0 18.0 20.0 21.0 22.0 24.0 °CWB -15.0 12.52 7.48 12.41 7.59 12.32 7.73 12.29 7.80 12.27 7.89 12.15 8.02...
  • Page 87 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables  3Ø Synchro Equlvalent capacity table Max Power Input of each model is tabulated below (Duo) Model CT24 NP2(4) * 2 CM24 N14 * 2 CV24 NJ2 * 2 CB24L N32 * 2 5.06 5.06 5.06...
  • Page 88 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.13 AUUW608WD2 [UU61W U32] Cooling Capacity  ATNH60GMLE2 [UT60 NM2] Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB...
  • Page 89 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables  3Ø Synchro Equlvalent capacity table Max Power Input of each model is tabulated below (Duo) Model UT30 NP2(4) * 2 UM30 N14 * 2 UV30 NJ2 * 2 5.80 5.80 5.80 (Trio) Model...
  • Page 90 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables Heating Capacity  ATNH60GMLE2 [UT60 NM2] Indoor Air Temperature : °CDB Outdoor Air Temp. 16.0 18.0 20.0 21.0 22.0 24.0 °CWB -15.0 13.31 9.06 13.18 9.19 13.09 9.36 13.06 9.44 13.03 9.55 12.91 9.71...
  • Page 91 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables  3Ø Synchro Equlvalent capacity table Max Power Input of each model is tabulated below (Duo) Model UT30 NP2(4) * 2 UM30 N14 * 2 UV30 NJ2 * 2 5.70 5.70 5.70 (Trio) Model...
  • Page 92 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.14 AUUW70LAE [UU70W U34] Cooling Capacity  ABNW70GB9A0 [UB70 N94] Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB...
  • Page 93 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables Heating Capacity  ABNW70GB9A0 [UB70 N94] Indoor Air Temperature : °CDB Outdoor Air Temp. 16.0 18.0 20.0 22.0 24.0 °CWB -20.0 10.25 2.35 10.16 2.88 10.07 3.41 9.98 4.24 9.90 5.06 -15.0 13.34 3.41...
  • Page 94 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables 6.15 AUUW85LAE [UU85W U74] Cooling Capacity  ABMW85GB9A0 [UU85 N94] Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20.0 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0 °CDB...
  • Page 95 Single CAC Outdoor Unit Standard Inverter 6. Capacity Tables Heating Capactiy  ABMW85GB9A0 [UU85 N94] Indoor Air Temperature : °CDB Outdoor Air Temp. 16.0 18.0 20.0 22.0 24.0 °CWB -20.0 13.42 4.36 13.30 4.88 13.18 5.40 13.07 6.06 12.96 6.73 -15.0 16.87 5.40...
  • Page 96: Capacity Coefficient Factor

    Single CAC Outdoor Unit Standard Inverter 7. Capacity Coefficient Factor 7.1 Rate of change in capacity due to the main piping length 1 Phase Inverter  Rate of change in cooling capacity Piping length(m) 2.5/3.5 kW 99.8 99.3 98.8 5.0 kW 99.8 99.3 98.8...
  • Page 97: Operation Range

    Single CAC Outdoor Unit Standard Inverter 8. Operation Range Cooling Heating Continuous Operation Continuous Operation 10 12 23 25 Indoor Temperature [℃ WB] Indoor Tem [°C D B]...
  • Page 98 Single CAC Outdoor Unit Standard Inverter 8. Operation Range Only for AUUW70LAE [UU70W U34], AUUW85LAE [UU85W U74] Cooling Heating Continuous Operation Continuous Operation 10 12 23 25 Indoor Tem [°C D B] Indoor Temperature [℃ WB]...
  • Page 99: Electric Characteristics

    Single CAC Outdoor Unit Standard Inverter 9. Electric Characteristics Wiring of Main Power Supply and Equipment Capacity 1. The power supply work is needed only to the outdoor unit. The power supply to the indoor unit is conducted through the transmission wiring. Therefore, the power supply work can be carried out at just one place of the outdoor unit.
  • Page 100 Single CAC Outdoor Unit Standard Inverter 9. Electric Characteristics [ Field Wiring (Single Phase, 2 Wiring Type) ] Power supply Circuit breaker Earth Outdoor unit ※ This figure is representative example for field wiring. Actual appearance of outdoor and indoor units could be different with installed product.
  • Page 101 Unit range Volts ATNH09GRLE2 5.00 0.043 0.25 0.020 0.40 [CT09 NR2] ABNW09GL2A2 5.00 0.043 0.25 0.095 0.80 [CB09L N22] AUUW09GA0 [UU09W UL0] AVNH09GELA2 5.00 0.043 0.25 0.030 0.40 [CV09 NE2] AQNH09GALA0 5.00 0.043 0.25 0.020 0.60 [CQ09 NA0] ATNH12GRLE2 5.80 0.043...
  • Page 102 Single CAC Outdoor Unit Standard Inverter 9. Electric Characteristics Outdoor Unit Combined Indoor Unit Unit Power Comp Phase No. of Voltage Model names Model Name MCA MFA MSC Unit range Volts ATNH42GMLE2 24.6 18.08 0.248 0.95 0.210 1.00 [UT42 NM2] AUUW426D2 ABNW42GM2A0 25.1...
  • Page 103 Sound Pressure Levels [dB(A)] Model Cooling Heating AUUW09GA0 [UU09W UL0] AUUW12GA0 [UU12W UL0] AUUW18GAE [UU18W UE4] AUUW24GAE [UU24W U44] AUUW30GAE [UU30W U44] AUUW366D2 [UU36W UO2] AUUW426D2 [UU42W U32]...
  • Page 104: Sound Levels

    Single CAC Outdoor Unit Standard Inverter 10. Sound Levels AUUW09GA0 [UU09W UL0] AUUW12GA0 [UU12W UL0] AUUW18GAE [UU18W UE4] Cooling Cooling Heating Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25...
  • Page 105 Single CAC Outdoor Unit Standard Inverter 10. Sound Levels AUUW426D2 [UU42W U32] AUUW486D2 [UU48W U32] AUUW606D2 [UU60W U32] AUUW428D2 [UU43W U32] AUUW488D2 [UU49W U32] AUUW608D2 [UU61W U32] AUUW70LAE [UU70W U34] AUUW85LAE [UU85W U74] ▲ Cooling ▲ Cooling ▲ Cooling Heating Heating Heating NC-65...
  • Page 106 5. Sound level will vary depending on a range of factors such as the construction (acoustic absorption coefficient) of particular room in which the equipment in installed. Sound Power Level [dB(A)] Model Cooling AUUW09GA0 [UU09W UL0] AUUW12GA0 [UU12W UL0] AUUW18GAE [UU18W UE4] AUUW24GAE [UU24W U44] AUUW30GAE [UU30W U44]...
  • Page 107 Single CAC Outdoor Unit Standard Inverter 10. Sound Levels AUUW366D2 [UU36W UO2] AUUW24GAE [UU24W U44] AUUW30GAE [UU30W U44] AUUW368D2 [UU37W UO2] NR-90 NR-90 NR-85 NR-85 NR-80 NR-80 NR-75 NR-75 NR-70 NR-70 NR-65 NR-65 NR-60 NR-60 NR-55 NR-55 NR-50 NR-50 NR-45 NR-45 NR-40 NR-40...
  • Page 108 Outdoor Unit Standard Inverter - Synchro Single CAC 1.Power Supply 2.List of Functions 3.Combination Table 4.Piping Length & Height 5.Simultaneous Operation Setting 6.Piping Diagrams 7.Accessories...
  • Page 109: Power Supply

    Single CAC Outdoor Unit Standard Inverter - Synchro 1. Power Supply Type OutdoorUnit Capacity(kW) Circuit BreakerCapacity PowerSupply AUUW426D2 [UU42W U32] 12.5 1 Phase AUUW486D2 [UU48W U32] 14.0 1Ø, 220-240 V, 50Hz Inveter AUUW606D2 [UU60W U32] 15.0 AUUW428D2 [UU43W U32] 12.5 AUUW488D2 [UU49W U32] 14.0 3 Phase...
  • Page 110: List Of Functions

    Single CAC Outdoor Unit Standard Inverter - Synchro 2. List of Functions 1 Phase Inverter - Synchro AUUW426D2 AUUW486D2 AUUW606D2 Category Functions [UU42W U32] [UU48W U32] [UU60W U32] Defrost / Deicing High pressure switch Low pressure switch Reliability Phase protection Restart delay (3-minutes) Self diagnosis Soft start...
  • Page 111 Single CAC Outdoor Unit Standard Inverter - Synchro 2. List of Functions 3 Phase Inverter - Synchro AUUW428D2 AUUW488D2 Category Functions [UU43W U32] [UU49W U32] Defrost / Deicing High pressure switch Low pressure switch Reliability Phase protection Restart delay (3-minutes) Self diagnosis Soft start Test function...
  • Page 112 Single CAC Outdoor Unit Standard Inverter - Synchro 2. List of Functions AUUW608D2 AUUW70LAE AUUW85LAE Category Functions [UU61W U32] [UU70W U34] [UU85W U74] Defrost / Deicing High pressure switch Low pressure switch Reliability Phase protection Restart delay (3-minutes) Self diagnosis Soft start Test function Night Silent Operation...
  • Page 113: Combination Table

    Single CAC Outdoor Unit Standard Inverter - Synchro 3. Combination Table Possible combinations Possible combination of indoor units Synchro Trio Quartet IDU : INDOOR UNIT ODU : OUTDOOR UNIT BD : BRANACH DISTRIBUTOR UNIT REMO : WIRED REMOTE CONTROLLER REMO REMO REMO Ceiling...
  • Page 114: Synchro Operation

    Single CAC Outdoor Unit Standard Inverter - Synchro 4. Piping Length & Height Synchro Operation Install the branch pipe so that pipe length and difference between high and low will not exceed below Spec. Indoor Unit Indoor Unit Indoor Unit Indoor Unit Branch Notes...
  • Page 115 Single CAC Outdoor Unit Standard Inverter - Synchro 5. Simultaneous Operation Setting 12.5~15.0kW Outdoor Unit PCB Setting Procedure 1. SW01N (PIP SW2) Setting Set the SW01N (PIP SW2) as below Table ( ) 2. Auto Addressing Method Addressing work assigns address to each indoor unit. When firstly installing product or replacing the indoor unit PCB.
  • Page 116 Single CAC Outdoor Unit Standard Inverter - Synchro 5. Simultaneous Operation Setting 2. Auto Addressing Method Addressing work assigns address to each indoor unit. When firstly installing product or replacing the indoor unit PCB. Auto Addressing work should be done for simultaneous operation. •...
  • Page 117: Piping Diagrams

    Single CAC Outdoor Unit Standard Inverter - Synchro 6. Piping Diagrams "Synchro" Duo AUUW426D2 [UU42W U32], AUUW486D2 [UU48W U32], AUUW606D2 [UU60W U32] AUUW428D2 [UU43W U32], AUUW488D2 [UU49W U32], AUUW608D2 [UU61W U32] AUUW70LAE [UU70W U34], AUUW85LAE [UU85W U74] INDOOR UNIT Heat exchanger Heating Thermistor for suction air...
  • Page 118 Single CAC Outdoor Unit Standard Inverter - Synchro 6. Piping Diagrams "Synchro" Trio AUUW426D2 [UU42W U32], AUUW486D2 [UU48W U32], AUUW606D2 [UU60W U32] AUUW428D2 [UU43W U32], AUUW488D2 [UU49W U32], AUUW608D2 [UU61W U32] AUUW70LAE [UU70W U34], AUUW85LAE [UU85W U74] INDOOR UNIT Heat exchanger Heating Thermistor for suction air...
  • Page 119 Single CAC Outdoor Unit Standard Inverter - Synchro 6. Piping Diagrams "Synchro" Quartet AUUW426D2 [UU42W U32], AUUW486D2 [UU48W U32], AUUW606D2 [UU60W U32] AUUW428D2 [UU43W U32], AUUW488D2 [UU49W U32], AUUW608D2 [UU61W U32] AUUW70LAE [UU70W U34], AUUW85LAE [UU85W U74] Indoor Unit Heat exchanger Heating Thermistor for suction air...
  • Page 120: Optional Accessories

    Single CAC Outdoor Unit Standard Inverter - Synchro 7. Accessories Optional accessories Name ModelNo. Indoorclassification CapacityRatio(%) PMUB11A "Synchro" Duo 50:50(1:1) Branch Kit PMUB111A "Synchro" Trio 33:33:33(1:1:1) PMUB1111A "Synchro" Quartet 25:25:25:25(1:1:1:1)
  • Page 121 Outdoor Unit Compact Inverter Single CAC 1.List of Functions 2.Specifications 3.Dimensions 4.Piping Diagrams 5.Wiring Diagrams 6.Capacity Tables 7.Capacity Coefficient Factor 8.Operation Range 9.Electric Characteristics 10.Sound Levels...
  • Page 122 Single CAC Outdoor Unit Compact Inverter 1. List of Functions AUUW18GC0 [UU18WC UL0], AUUW24GC0 [UU24WC UE0] Category Functions AUUW30GC0 [UU30WC UE0], AUUW36GC0 [UU36WC U40] Defrost / Deicing High pressure switch Low pressure switch Reliability Phase protection Restart delay (3-minutes) Self diagnosis Soft start Test function Night Silent Operation...
  • Page 123: Specifications

    Single CAC Outdoor Unit Compact Inverter 2. Specifications Combinational Specifications AUUW18GC0 AUUW24GC0 Outdoor unit [UU18WC UL0] [UU24WC UE0] Combination ABNW18GBHC0 ABNW24GBHC0 Indoor unit [UB18C NH0] [UB24C NH0] Min.~Rated~Max. 1.80 ~ 4.70 ~ 5.10 2.70 ~ 6.80 ~ 7.40 Cooling Min.~Rated~Max. Btu/h 6,140 ~ 16,040 ~ 17,410 9,210 ~ 23,210 ~ 25,260...
  • Page 124: Outdoor Unit Specifications

    Single CAC Outdoor Unit Compact Inverter 2. Specifications Outdoor Unit Specifications AUUW18GC0 AUUW24GC0 Outdoor unit [UU18WC UL0] [UU24WC UE0] Power Supply V , Ø , Hz 220-240 / 1 / 50 220-240 / 1 / 50 Cooling Max. Starting Current Heating Max.
  • Page 125 Single CAC Outdoor Unit Compact Inverter 2. Specifications AUUW30GC0 AUUW36GC0 Outdoor unit [UU30WC UE0] [UU36WC U40] Power Supply V , Ø , Hz 220-240 / 1 / 50 220-240 / 1 / 50 Cooling Max. Starting Current Heating Max. Power Supply Cable No.
  • Page 126 Single CAC Outdoor Unit Compact Inverter 3. Dimensions AUUW18GC0 [UU18WC UL0]...
  • Page 127 Single CAC Outdoor Unit Compact Inverter 3. Dimensions AUUW24GC0 [UU24WC UE0] / AUUW30GC0 [UU30WC UE0]...
  • Page 128 Single CAC Outdoor Unit Compact Inverter 3. Dimensions AUUW36GC0 [UU36WC U40]...
  • Page 129 Single CAC Outdoor Unit Compact Inverter 4. Piping Diagrams Outdoor Unit Inlet Air Temperature Refrigerant Flow Condenser Out Thermistor Temperature Thermistor Cooling Heating Condensing Temperature Thermistor Flare Connection Electronic Expansion Strainer Strainer Valve Liquid Side Piping Pressure Sensor Gas Side Piping 4 way Valve...
  • Page 130: Wiring Diagrams

    Single CAC Outdoor Unit Compact Inverter 5. Wiring Diagrams Models : AUUW18GC0 [UU18WC UL0]...
  • Page 131 Single CAC Outdoor Unit Compact Inverter 5. Wiring Diagrams Models : AUUW24GC0 [UU24WC UE0], AUUW30GC0 [UU30WC UE0]...
  • Page 132 Single CAC Outdoor Unit Compact Inverter 5. Wiring Diagrams Models : AUUW36GC0 [UU36WC U40]...
  • Page 133: Cooling Capacity

    Single CAC Outdoor Unit Compact Inverter 6. Capacity Tables 6.1 Models : AUUW18GC0 + ABNW18GBHC0 [UU18WC UL0] [UB18C NH0] Cooling Capacity Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0...
  • Page 134 Single CAC Outdoor Unit Compact Inverter 6. Capacity Tables 6.2 Models : AUUW24GC0 + ABNW24GBHC0 [UU24WC UL0] [UB24C NH0] Cooling Capacity Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0...
  • Page 135 Single CAC Outdoor Unit Compact Inverter 6. Capacity Tables 6.3 Models : AUUW30GC0 + ABNW30GM1A0 [UU30WC UE0] [UM30 N14] Cooling Capacity Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0...
  • Page 136 Single CAC Outdoor Unit Compact Inverter 6. Capacity Tables 6.4 Models : AUUW36GC0 + ABNW36GM2A0 [UU36WC U40] [UM36 N24] Cooling Capacity Indoor Air Temperature : °CDB / °CWB Outdoor Air Temp. 20 / 14.0 22.0 / 16.0 25.0 / 18.0 27.0 / 19.0 30.0 / 22.0 32.0 / 24.0...
  • Page 137 Single CAC Outdoor Unit Compact Inverter 7. Capacity Coefficient Factor 7.1 Rate of change in capacity due to the main piping length  Rate of change in cooling capacity Piping length(m) 5.0/7.0 kW 99.3 97.9 96.6 93.8 Rate of change in capacity(%) 8.0 kW 99.3 97.9...
  • Page 138: Operation Range

    Single CAC Outdoor Unit Compact Inverter 8. Operation Range Models : AUUW18GC0 [UU18WC UL0], AUUW30GC0 [UU30WC UE0] AUUW36GC0 [UU36WC U40] Cooling Heating Continuous Operation Continuous Operation Indoor Temp. [°C DB]...
  • Page 139 Single CAC Outdoor Unit Compact Inverter 8. Operation Range Models : AUUW24GC0 [UU24WC UE0] Heating Cooling Continuous Operation Continuous Operation Indoor Temp. [°C DB]...
  • Page 140: Electric Characteristics

    Single CAC Outdoor Unit Compact Inverter 9. Electric Characteristics Wiring of Main Power Supply and Equipment Capacity 1. The power supply work is needed only to the outdoor unit. The power supply to the indoor unit is conducted through the transmission wiring. Therefore, the power supply work can be carried out at just one place of the outdoor unit.
  • Page 141 Single CAC Outdoor Unit Compact Inverter 9. Electric Characteristics Combined Indoor Unit Unit Power Supply COMP Outdoor Unit No. of Voltager Model names Model names Volts MSC RLA Units ange (MOP) AUUW18GC0 ABNW18GBHC0 12.6 10.0 0.043 0.25 0.154 0.80 [UU18WC UL0] [UB18C NH0] AUUW24GC0 ABNW24GBHC0...
  • Page 142 Single CAC Outdoor Unit Compact Inverter 10. Sound Levels 10.1 Sound Pressure Levels Overall Note 1.Data is valid at free field condition. 2.Reference accoustic pressure 0dB = 20μPa. 3.Data is valid at nominal operation condition. Refer to the Model Specifications for nominal conditions(Power source and Ambient temperature, etc) 4.Sound levels can be increased in accordance with 1.5m...
  • Page 143: Sound Levels

    Single CAC Outdoor Unit Compact Inverter 10. Sound Levels AUUW36GC0 [UU36WC U40] ▲ Cooling Heating NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 Approximate NC-20 Hearing Threshold NC-15 1000 2000 4000 8000 Octave Band Center Frequency (Hz)
  • Page 144 Single CAC Outdoor Unit Compact Inverter 10. Sound Levels 10.2 Sound Power Levels Note 1. Data is valid at diffuse field condition. 2. Reference acoustic intensity 0dB = 10E-6μW/m 3. Sound power level is measured on the rated condition in the reverberation rooms. Refer to the Model Specifications for nominal conditions(Power source and Ambient temperature, etc) 4.
  • Page 145 Single CAC Outdoor Unit Compact Inverter 10. Sound Levels AUUW36GC0 [UU36WC U40] NR-90 NR-85 NR-80 NR-75 NR-70 NR-65 NR-60 NR-55 NR-50 NR-45 NR-40 NR-35 NR-30 1000 2000 4000 8000 Octave Band Center Frequency (Hz)
  • Page 146: Installation Of Outdoor Units

    MULTI/SINGLE CAC Installation of Outdoor Units MULTI/SINGLE CAC 1.Select the Best Location 2.Installation Space 3.Installation of Outdoor Unit 4.Refigerant piping system 5.Installation guide at the seaside 6.Seasonal wind and caution in winter...
  • Page 147: Select The Best Location

    MULTI/SINGLE CAC Installation of Outdoor Units 1. Select the Best Location Select space for installing outdoor unit, which will meet the following conditions: • No direct thermal radiation from other heat sources • No possibility of annoying neighbors by noise from unit •...
  • Page 148 MULTI/SINGLE CAC Installation of Outdoor Units 2. Installation Space 2.1 Clearance around outdoor units • Ensure that the space around the back is 300 mm or more 300 mm or more 300 mm or more more than 300 mm on the or more opposite to the PCB side and secure 600 mm space near the compressor and PCB...
  • Page 149: Installation Space

    MULTI/SINGLE CAC Installation of Outdoor Units 2. Installation Space Where there is an obstacle on the air intake side:  No obstacle above [Unit : mm(inch)] • Obstacle on the suction side only • Obstacle on the both sides  Obstacle above, too [Unit : mm(inch)] •...
  • Page 150 MULTI/SINGLE CAC Installation of Outdoor Units 2. Installation Space Where there are obstacles on both suction and discharge sides:  Where the obstacles on the discharge side is higher than the unit: [Unit : mm(inch)] • No obstacle above • Obstacle above, too The relations between H, A and L are as follows: A[mm(inch)] 750(29 1/32)
  • Page 151: Series Installation

    MULTI/SINGLE CAC Installation of Outdoor Units 2. Installation Space Series installation [Unit : mm(inch)] • One row of stand alone installation • Rows of collective installation (2 or more) • L should be smaller than H L ≤ H 300(11-13/16) 300(11-13/16) or more or more...
  • Page 152 MULTI/SINGLE CAC Installation of Outdoor Units 3. Installation of Outdoor Unit 3.1 Foundation for Installation • Fix the unit tightly with bolts as shown below so that unit will not fall down due to earthquake or gust. • Use the H-beam support as a base support. •...
  • Page 153 MULTI/SINGLE CAC Installation of Outdoor Units 3. Installation of Outdoor Unit 3.2 Settlement of the outdoor unit • Anchor the outdoor unit with a bolt and nut tightly and horizontally on a concrete or rigid mount. • When installing on the wall, roof or rooftop, anchor the mounting base securely with a nail or wire assuming the influence of wind and earthquake.
  • Page 154 MULTI/SINGLE CAC Installation of Outdoor Units 4. Refrigerant piping system 4.1 Piping System between outdoor unit / indoor unit Single type CAUTION • Please check the product type. Piping installation and refrigerant charge varies depending on the type of product. For more information, please refer to the installation manual.
  • Page 155: Refrigerant Piping System

    MULTI/SINGLE CAC Installation of Outdoor Units 4. Refrigerant piping system Single type - Synchro CAUTION • Please check the product type. Piping installation and refrigerant charge varies depending on the type of product. For more information, please refer to the installation manual. Indoor Unit Indoor Unit Indoor Unit...
  • Page 156: Selecting The Location(Outdoor Unit)

    MULTI/SINGLE CAC Installation of Outdoor Units 5. Installation guide at the seaside CAUTION 1. Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced. 2. Do not install the product where it could be exposed to sea wind (salty wind) directly. It can result corrosion on the product.
  • Page 157: Seasonal Wind And Cautions In Winter

    MULTI/SINGLE CAC Installation of Outdoor Units 6. Seasonal wind and cautions in winter • Sufficient measures are required in a snow area or severe cold area in winter so that product can be operated well. • Get ready for seasonal wind or snow in winter even in other areas. •...
  • Page 158 LG Electronics Inc, 128, Yeoui-daero, Yeongdeungpo-gu, Seoul, Korea (07336) http://partner.lge.com The air conditioners manufactured by LG have received ISO9001 certificate for quality assurance Copyright © 2016 - 2018 LG Electronics Inc. and ISO14001 certificate for environmental management system. All Rights Reserved.

Table of Contents