Assembling Stacked Ovens; Leveling; Electrical Connections - Vulcan-Hart ECO2C ML-114572 Installation And Operation Manual

Electric convection ovens
Table of Contents

Advertisement

ASSEMBLING STACKED OVENS

Determine which oven will be on the bottom and place it on its left side, being careful to avoid scratching
the finish. Install the four legs, using the 24 bolts and lockwashers provided (6 per leg).
Place lower oven (with legs) on floor. Remove the two
3
top cover and the 1
installation position.
Install the two locating studs (included in leg stack set) into the screw plates on the underside of the
top oven (Fig. 2) and remove the 1
the bottom oven. Carefully place the top oven in position above the bottom oven.

LEVELING

Once the oven is in its permanent position, place a carpenter's level on the oven rack. If the oven is
installed on legs, turn adjustable feet in or out to level oven front-to-back and side-to-side. If the oven
is installed on casters, loosen set screws and turn casters in or out to level oven front-to-back and side-
to-side. Retighten set screws after leveling.

ELECTRICAL CONNECTIONS

WARNING:
ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING: DISCONNECT THE ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.
TOTAL
Single Oven
Stacked Oven
Knockouts are provided on the back and bottom of the oven for making conduit connections. Remove
the screws from the front control panel for access to the terminal block.
Wire and required hardware for making connections between stacked ovens are furnished with the leg
stack set.
Replace the right side panel if it was removed during electrical connection.
Replace the front control panel and turn on the power supply.
"
knockout on the right side of the top cover. Move this oven to the
(2.8 cm)
32
3
"
(2.8 cm)
32
ELECTRICAL DATA
3-PHASE LOADING
(KW PER PHASE)
KW
L1-L2 L2-L3 L1-L3
5.5
2.5
0
3.0
11.0
5.0
0
6.0
7
"
(1.1 cm)
16
knockout that will line up with the one removed from
NOMINAL AMPS PER LINE WIRE
3 PHASE
208V.
L1
L2
L3
L1
23.0
10.0
12.0
20.0
46.0
20.0
24.0
40.0
– 5 –
knockouts on each side of the
1 PHASE
240V.
208V. 240V.
L2
L3
9.0
11.0
26.0
18.0
22.0
52.0
23.0
46.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eco2d ml-114570