Note: The base refractory must be
removed to access screws.
BASE REFRACTORY
Figure 4.6 Base Refractory Removal
Figure 4.8 Burner Identification
6000CLX
NOTCH LOCATION
BURNER BOTTOM
6000CLX
8000CLX
Heat & Glo • 6000CLX-IFT, 8000CLX-IFT Owner's Manual • 2506-981 Rev. K • 8/20
Figure 4.7 Valve Assembly Removal
Burner Identification/Verification
The burner may be accessed for identification and veri-
fication purposes. This task should be performed by a
qualified service technician. The base refractory, valve
plate, refractory and grate do not need to be removed to
access the burner assembly. The logs and fiber burner
top need to be removed to access the burner. Disconnect
the pilot from the burner before removal. See Figure 4.8
for burner identification chart. Notch patterns are located
on bottom side of burner.
8000CLX
NOTCH LOCATION
NG
PROPANE
BURNER BOTTOM
Note: Notch location may vary by model.