Spray Tip Selection Chart
AEF Fine Finish Pre-Orifice Spray

Tips

Recommended for high finish quality applications at low and medium pressures. AEF tips have a pre-orifice that
assists in atomizing sheer thinning materials, including lacquers.
Order desired tip, Part No. AEFxxx, where xxx = 3–digit number from the matrix below.
Orifice
Fluid Output
Size
fl oz/min (l/min)
in. (mm)
at 600 psi
(4.1 MPa,
41 bar)
† 0.010
9.5 (0.28)
(0.254)
0.012
12.0 (0.35) 16.0 (0.47)
(0.305)
0.014
16.0 (0.47) 21.0 (0.62)
(0.356)
0.016
20.0 (0.59) 26.5 (0.78)
(0.406)
* Tips are tested in water.
Fluid output (Q) at other pressures (P) can be calculated by this formula: Q = (0.041) (QT)
output (fl oz/min) at 600 psi from the above table for the selected orifice size.
† These tip sizes include a 150 mesh filter.
72
at 1000 psi
6-8 (150-
(7.0 MPa,
200)
70 bar)
12.5 (0.37)
310
312
314
Maximum Pattern Width at 12 in. (305 mm)
in. (mm)
8-10 (200-
10-12
250)
(250-300)
Spray Tip
410
510
412
512
414
514
416
516
12-14
14-16
(300-350)
(350-400)
610
710
612
712
614
714
616
716
where QT = fluid
16-18
(400-450)
812
814
3A2497C