Daily System Care - Graco WB3000 Instructions - Parts Manual

Isolation system & pro
Hide thumbs Also See for WB3000:
Table of Contents

Advertisement

Daily System Care

1. Follow the instructions under
Clean the Gun Daily, page
the
Pressure Relief Procedure, page
2. Clean the fluid and air filters.
3. Check for fluid leaks. Tighten all fittings.
4. Clean workpiece hangers. Use non-sparking
tools.
5. Check the movement of the trigger and valves.
Lubricate if necessary.
6.
Check Gun Electrical Grounding, page
3A2497C
33. Follow
26.
23.
7. Hang the gun from its hook, with the nozzle
pointing down.
8. Clean the cabinet:
• Inspect the cabinet and clean up any spilled
paint. Conductive paint residue allowed to
contact grounded parts may short out the
electrostatics.
• Keep the inside of the cabinet clean, for proper
operation.
• Inspect the door T-handle locking screw
regularly, to ensure the threads are well
greased. Apply silicone-free grease to the
threads when necessary.
• Visually inspect the ground strip (240)
for damage. Replace if needed.
Measure the resistance weekly. See
Test Ground Strip Resistance, page
Maintenance
39.