PANEL SETTINGS

For the SEM to communicate with the panel and report all alarms,
the following VISTA settings need to be set at the panel. These settings
are automatically changed during first power up after account creation so
no further action should need to be taken. Here is a list of the automatic
programming changes, for reference.
ENABLE IP/GSM
*29 IP/GSM needs to be set to [1]. This will ensure that the panel
is communicating with the SEM.
SILENT ALARMS
For the SEM to report silent and duress alarms, the following VISTA
settings are automatically changed at the panel.
*41 Primary Phone No. needs to be cleared.
*42 Secondary Phone No. needs to be cleared.
*43 Partition 1 Primary Acct. No. needs to be set to a four-digit
number. Alarm.com automatically set this setting to 1234.
*45 Partition 2 Primary Acct. No. needs to be set to a four-digit
number. Alarm.com automatically set this setting to 4321.
*48 Report Format needs the primary phone number format
set to [77].
*55 Dynamic Signaling Priority needs to be set to [1].
*64 Test Report Code needs to be set to [1,0].
*92 Phone Line Monitor Enable needs to be set to [0,0].
The Zone 92 reporting code needs to be enabled for duress reporting.
The customer's actual Central Station Forwarding Settings
TIP:
should be set up on the Alarm.com Partner Portal.
BYPASS OPEN SENSORS
Before the customer can use the bypass open sensors feature on the
Customer Website or Mobile App, *23 Quick (Forced) Bypass needs to
be enabled. This setting is not automatically enabled. If the customer
would like to use this feature on the Customer Site or Mobile App,
please enable this setting.