Does the SEM support reporting multiple alarms on a single zone
(Swinger Suppression *93)?
The SEM will only report one instance of each alarm per alarm event
regardless of the settings specified on the panel in the *93 programming
menu. The SEM does not support reporting multiple alarms on a
single zone.
Is the SEM compatible with POTS?
No, the SEM should be the only communication path for alarm signaling
to the central station.
How does SEM handle dialer delay?
The SEM uses the Dialer Delay value that is stored in the panel. This value
can be changed using the Partner Portal, MobileTech, or on the panel in
programming section *50.
Is the SEM compatible with Honeywell's Street Smart Series
Code Encryptors?
Yes, the SEM is compatible with Honeywell's Street Smart Series
Code Encryptors. As with other touchscreen keypads or AUI devices on
a system with a Code Encryptor, the following steps will need to be
followed to install the SEM.
1.
Disconnect power from the panel.
2.
Disconnect the touchscreen keypad or AUI device from
the panel.
3.
Install the SEM, following the SEM installation steps
(without the touchscreen keypad or AUI device connected).
4.
Once the SEM is installed and working properly, power down
the system.
5.
Reconnect the touchscreen keypad or AUI device.
6.
Restore power to the panel and SEM.
Does the SEM support multiple partitions?
The SEM does support partitions. The panel can have up to the maximum
number of partitions the panel supports; however, zones are not supported
throughout all partitions. Zones should only be enrolled in a single partition.
Zones in multiple partitions are not supported by the SEM.
Can I can add and delete sensors remotely?
Yes, sensors can be added, changed, or deleted using MobileTech or the
Remote Toolkit on the Partner Portal.
Are the additional terminals on the SEM circuit board used or
needed for the install?
No, these terminals are for future development. Please disregard the relay,
zone, ring, and tip terminals on the SEM circuit board.
Does the SEM support Cross Zones?
No, the SEM does not support the Cross Zone attribute. The SEM will not
report the Cross Zone event to the central station.