Error code
E099
Communication between the Y servo DSP
and ESC is interrupted
E100
Communication between the Y servo net-
work cable and host is interrupted
E101
Exclusive for reading the Y servo PDO com-
munication parameter
E102
Y servo PDO communication has no index
E103
Y servo PDO communication synchroniza-
tion time is out of range
E104
Y servo PDO communication data is out of
range
E105
Y servo UVW short circuit
E106
Y servo inertia identification has failed
E107
Y servo encoder EEPROM reading / writing
has failed
E108
Y servo positive position limit
E109
Y servo position negative limit
E110
Y servo electronic gear ratio range
E111
Y servo input pulse frequency is too high
E200
XY drive alarm
E201
X drive alarm
E202
Y drive alarm
E203
Spindle returns to the initial position
E204
Main motor direction is wrong
E205
Pressure frame fails to come down
E206
Head board failure
E207
Input I/O timeout error
E208
Insufficient air pressure
E209
Clipper motor is not at the correct position
E210
Presser motor is not at the correct position
E211
Wire grab motor is not at the correct posi-
tion
E212
Cutter is not at the correct position
E213
Wire breaks
E214
Number of jobs is too many
E215
Bottom line has been already used up
E216
File size is too large
Error description
Click the "Press the frame" button to place the frame.
The head plate has broken. It is necessary to change the
broken head plate with a new one.
Check whether the input IO has "high" or "low" of the input
signal.
Check whether the air supply unit supplies air normally.
Check whether the zero signal of the clipper motor is nor-
mal.
Check that the zero signal of the presser foot motor is nor-
mal.
Check whether the zero line signal of the wire grab motor
is normal.
Check whether the zero signal of the cutter motor is nor-
mal.
Execute the thread again or turn OFF the wire break detec-
tion function before proceeding the operation.
Counted value on the counter has reached the total
number you have set. The total number on the counter is
cleared and the counter re-starts counting by re-starting
the operation.
It is necessary to change the bobbin thread hook.
The number of pins in the graphics file has exceeded
the maximum range. The current graphics file must be
changed with a new one.
– 42 –