Torque Values And Cable Sizes - SMA Sunny Boy 6000TL‑US Installation Manual

Pv inverter
Hide thumbs Also See for Sunny Boy 6000TL‑US:
Table of Contents

Advertisement

SMA America, LLC
11.9 Torque Values and Cable Sizes
Sunny Boy
AC terminal block
DC terminal block
Attachment to the wall mounting
bracket
Enclosure lid
DC Disconnect
AC terminal block
DC terminal block
Terminal block grounding
conductor
Attachment to the wall mounting
bracket
Enclosure lid
*see National Electrical Code
Installation Manual
in-lb.
40
40
44
53
40
40
40
44
44
®
, 310.16
Nm
4.5
6 to 2 AWG (16 to 35 mm²)
copper wire, rated for 194°F
4.5
8 to 2 AWG (10 to 35 mm²)
copper wire, rated for 194°F
5
6
4.5
6 to 2 AWG (16 to 35 mm²)
copper wire, rated for 194°F
4.5
8 to 2 AWG (10 to 35 mm²)
copper wire, rated for 194°F
4.5
8 to 2 AWG (10 to 35 mm²)
copper wire, rated for 194°F
5
5
SB6-11TL-US-IA-en-13
11  Technical Data
Wire size
(90°C)*
(90°C) *
-
-
(90°C)*
(90°C) *
(90°C) *
-
-