Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters
Alcove Installation
6"
(150mm)
Sidewall/
Trim
PDV20
ST381
Fig. 5 Alcove installation.

Mantel Clearances

Combustible
Mantel or Trim
Materials
B
3" (75mm) Min.
PDV20 and SDVR
A (Max.)
9"
(230mm)
7 "
(190mm)
6"
(152mm)
4 "
(114mm)
3"
(76mm)
1 "
(38mm)
A = Depth of Mantel and/or Top Trim
B = Height from Top of Heater
Fig. 6 Mantel / top trim clearances.
6
9"
(230mm)
Max. Mantel
Width
See
Fig. 6
2 "
(63mm)
Rear Wall
A
Noncombustible
Materials
ST382
B (Min.)
10 "
(270mm)
9"
(230mm)
7 "
(190mm)
6"
(152mm)
4 "
(114mm)
3"
(75mm)
6"
(150mm)
Sidewall/
Trim
SDVR

Hearth Requirements

The PDV20 and SDVR Heaters must be installed on
rigid flooring. When the heater is installed directly on
any combustible surface other than wood flooring, a
metal or wood panel extending the full width and depth
of the unit must be used as the hearth. There are no
other hearth requirements.

Gas Specifications

Model
Fuel
Gas Control
PDV20RN
Nat
PDV20RP
Prop
PDV20RFN
Nat
Comfort Control
PDV20RFP
Prop
Comfort Control
SDVRRN
Nat
SDVRRP
Prop
SDVRRFN
Nat
Comfort Control
SDVRRFP
Prop
Comfort Control
Weight: Fully assembled 350 lbs.

Gas Inlet and Manifold Pressures

Inlet Minimum
Inlet Maximum
Manifold Pressure
9"
(230mm)
Max. Mantel
Width
See
Fig. 6
2 "
(63mm)
Rear Wall
ST381a
Max.
Min.
Input
Input
BTU/h
BTU/h
Millivolt
21,000
15,500
Millivolt
21,000
16,500
21,000
15,500
21,000
16,500
Millivolt
21,000
15,500
Millivolt
21,000
16,500
21,000
15,500
21,000
16,500
Natural
LP (Propane)
5.5" w.c.
11.0" w.c.
14.0" w.c.
14.0" w.c.
3.5" w.c.
10" w.c.
20007066