Clearance to Combustibles

Top of Unit to Ceiling ................................32" (813 mm)
Front of Unit to Combustibles ...................36" (914 mm)
Appliance
Top of Standoff .........................................0" (0 mm)
Bottom ......................................................0" (0 mm)
Side .....................................................3/4" (19 mm)
Back .........................................................0" (0 mm)
Venting
Concentric sections of DV Vent ....................1" (25 mm)
Nonconcentric sections of DV Vent
Sides and Bottom ...................................1" (25 mm)
Top .........................................................2" (51 mm)

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figs. 3a and 3b, and the following Mantel Charts.
The fitting of a bay window trim kit does not effect
the distances and reference points referred to in the
diagram and chart.
Noncombustible mantels and legs may be installed
at any height and width around the appliance. When
using paint or lacquer to finish the mantel, such paint or
lacquer must be heat resistant to prevent discoloration.
V
W
X
Y
Z
A
B
C
D
E
Fireplace
Front
Mantel Chart
CFM146
Mantel Shelf
DV Mantel Chart
7/5/01 sta
Ref.
or Breast Plate
Depth
V
10"
(254 mm)
W
8"
(203 mm)
X
6"
(152 mm)
Y
4"
(101 mm)
Z
2"
(51 mm)
Fig. 3a Combustible mantel minimum installation.
10009459
Maintain minimum 2¹⁄₂"
(64 mm) clearance to
combustible
Fireplace
Top of Combustion
Chamber
CFM146
Mantel from Top of
Ref.
Combustion Chamber
20DVT
A
18¹⁄₂" (470 mm)
B
16¹⁄₂" (419 mm)
C
14¹⁄₂" (368 mm)
D
12¹⁄₂" (318 mm)
E
10¹⁄₂" (267 mm)
Brookhaven Direct Vent Gas Fireplace
CFM164b
Side of Fireplace
CFM164b
Mantel Leg Char
DVT44
4/9/03 djt
Combustion
Opening
Mantel
Ref.
Leg Depth
CFM170
F
12 (305 mm)
DV Builder Front
View
G
9"
(229 mm)
H
6"
(152 mm)
I
4"
(102 mm)
J
3"
(76 mm)
Fig. 3b Combustible mantel leg minimum installation.

Hearth

A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which projects out 12" (305 mm) or more from
the front of the fireplace.
Cold climate installation recommendation:
When installing this unit against a
non-insulated exterior wall or chase,
it is mandatory that the outer walls
be insulated to conform to applicable
insulation codes.
Proposition 65 Warning: Fuels used in gas, wood-
burning or oil fired appliances, and the products of
combustion of such fuels, contain chemicals known to
the State of California to cause cancer, birth defects
and other reproductive harm.
California Health & Safety Code Sec. 25249.6
J
I
H
G
F
K
L
M
N
O
CFM170
Mantel Leg From Side
Ref.
of Comb. Opening
K
12"
(305 mm)
L
9"
(229 mm)
M
6"
(152 mm)
N
4"
(102 mm)
O
3"
(76 mm)